3. HARDWARE SETUP
MOUNTING NOTCH
J1M1
J1M2
CAPTIVE NUT
(back of riser)
Screw to secure
riser to case
ATTACH MOUNT
BRIDGE (top view)
4. Screw the captive nuts into the attach mount bridges.
WARNING!
Do not overtighten the captive nut. Doing so could damage your
motherboard. Tighten captive nuts to no more than 6±1inch/pound.
5. With the ejectors of the DIMM socket (J1M1/J1M2) in the open position and
while holding the riser along its edges, push down gently but firmly on one side
of the memory module until it snaps into place and then do the same on the other
side. The guides on the socket's ejectors should go through the two mounting
notches on the module and the ejectors should close. If necessary, push the ejec-
tors inward to secure the module in place.
IMPORTANT:
When populating both DIMM sockets, the module density on J1M2
must be greater than the one on J1M1. For example, if you are installing a 64MB
memory on J1M1, you must install memory greater than or equal to 64MB on J1M2.
Removing Memory from the Riser
1. Unscrew the captive nuts from the attach mount bridge.
2. Push both ejectors (J1M1/J1M2) outward while holding the module along its side
edges. Pull the module straight up and out of the DIMM sockets on the riser.
28
ASUS P3C-L / P3C-S / P3C-LS User's Manual
SDRAM
EJECTOR
RIBS (inside socket)
NOTCH KEYS
CONNECTORS
RIBS (inside socket)
EJECTOR
Screw to secure
riser to case
CAPTIVE NUT
(back of riser)
NOTCH KEYS
MOUNTING NOTCH
CONNECTORS
ATTACH MOUNT
BRIDGE (top view)
CPU FAN
RIMM0 (top view)