Vendor
Model Number
Revision
Temperature ( ℃ )
Humidity rate ( % )
Thermo Tracer
Test Program
Comments:
The component temperature measured value was based on 35℃ check in the chamber
and the system during in the 3Dmark2000 Looping testing.
51

THERMAL IMAGE TEST

Motherboard General Information
Biostar
U8598
V1.1
35 ℃
0 ~ 60 %
NEC TH5104
3Dmark2000