M
aintenance and care
Replace drive belt
1. Unplug the vacuum from electrical outlet.
2. With rotating floor brush removed from
vacuum cleaner (Steps 1-4 of check
rotating floor brush and drive belt),
grasp old drive belt and remove from
motor pulley. Discard the old drive belt.
3. Place new drive belt over motor pulley
and loop other end over rotating floor
brush in the space between the bristles.
NOTE: It is important that you use only
genuine BISSELL replacement belts.
Generic belts may not meet the exacting
specifications required to keep your
vacuum operating at its peak performance.
The use of unbranded belts could lead to
early failure of the vacuum and could void
your warranty.
4. Pull the rotating floor brush firmly
into position, stretching the drive belt,
and place ends of rotating floor brush
down into the slots on sides as shown.
Alignment of brush ends in slots may be
necessary to fully insert the brush.
5. Turn rotating floor brush by hand several
times in the direction of motor pulley. If
properly installed, drive belt will center
itself on rotating brush crown.
6. Insert front edge of brush cover, rotate
into place, and snap 3 latches.