Exhaust Requirements And Maintenance - LG DLE8377WM Owner's Manual

Electric and gas dryer
Hide thumbs Also See for DLE8377WM:
Table of Contents

Advertisement

Following
are important
instructions
and information
concerning
the exhaust
requirements
for your dryer.
,_t
Important
Warning:
To reduce the risk of fire, combustion,
or accumulation
of combustible
gases, DO NOT
exhaust
dryer air into an enclosed
and unventilated
area, such as an attic, wall, ceiling, crawl space, chimney,
gas
vent, or concealed
space of a building.
To reduce the risk of fire, DO NOT exhaust
the dryer with plastic or thin foil
ducting.
Recommended
M__.
(10.2 cm)
C
H
4 _'
(10.2 cm)
Use Only for Short Run
Installations
2-1/2"
(6.35 cm)
0
65 feet (19.8 m)
45 feet (13.7 m)
1
55 feet (16.8 m)
35 feet (10.7 m)
2
47 feet (14.3 m)
30 feet (9.1 m)
3
36 feet (11.0 m)
25 feet (7.6 m)
4
28 feet (8.5 m)
20 feet (6.1 m)
0
1
2
3
4
55 feet ( 16.8 m)
47 feet (14.3 m)
41 feet (12.5 m)
30 feet (9.1 m)
22 feet (6.7 m)
35 feet (10.7 m)
27 feet (8.2 m)
21 feet (6.4 m)
17 feet (5.2 m)
15 feet (4.5m)
NOTE : Deduct 6 feet (1.8 m) for each additional
elbow.
It is not recommended
to use more than 4 90 ° elbows.
Exhaust
Requirements
and Instructions:
1. Venting materials are not provided with the dryer
and you should obtain the necessary venting
materials locally. For example, the outer end of
exhaust pipe must have a weather hood with hinged
dampers to prevent back-draft
when the dryer is not
in use.
2. The exhaust duct must be t_ur inches (10.2 cm) in
diameter with no obstructions.
The exhaust duct
should be kept as short as possible. Make sure to
clean any old ducts before installing your new dryer.
3. Rigid or semi-rigid metal ducting is recommended
t_r use as transition ducting between the dryer and
and the wall. In special installations
when it is
impossible to make a connection
with the above
recommendations,
then a UL-listed flexible metal
transition duct may be used between the dryer and
wall connection only. The use of this ducting will
affect dry time.
4. DO NOT use sheet metal screws on exhaust pipe
joints or other fastening means which extend into
the duct that could catch lint and reduce the
efficiency of the exhaust system. Secure all joints
with duct tape.
5. To maximize operating results, please observe the
duct length limitations noted in the chart above.
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D8388nmD8388wmDlg8388wmDle8377nmDlg8388nm

Table of Contents