Test 6 Heater Switch Test - Electric Model - LG DLE2512W Service Manual

Electric & gas dryer
Hide thumbs Also See for DLE2512W:
Table of Contents

Advertisement

Test 6
Heater switch test - Electric Type
Caution
Trouble Symptom
Measurement Condition
TH3
TH2
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
(When discharging, contact the metal plug of Power cord with earth line.)
While operating, Heating will not work.
Drying time takes longer.
After turning Power off, measure the resistance.
1. Is resistance between Heater terminal
and
below 18 ~ 22Ω?
2. Is resistance between Heater terminal
and
below 18 ~ 22Ω?
3. Is resistance between Heater terminal
and
below 9 ~ 11Ω?
Check if the value of measured resistance is
below 1Ω between terminal TH2 (Safety Thermostat).
Check if the value of measured resistance is below
1Ω between terminal TH3 (HI-Limit Thermostat).
Check Motor. Check if the value of measured
resistance is below 1Ω between terminal
and
at RUN condition.
Check Controller.
Check Harness-linking Connector.
YES
YES
YES
YES
28
NO
• Replace Heater.
• Replace TH2
NO
(Safety Thermostat).
• Replace TH3
NO
(HI-Limit Thermostat).
• Check Motor and
NO
replace it.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dle2516wD2526Dlg2526wDle373Dle3733