HP AA979A - StorageWorks SAN Switch 2/8V Installation Instructions Manual page 4

Hp storageworks san switch rack mount kit installation instructions (a7511-90904, june 2009)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:

Advertisement

4.
Assemble the outer rails as follows:
a.
Attach the left outer rail and right outer rail to the rear mounting
brackets using two 1/4-20 hex nuts with captive star lock
washers attached loosely, as shown in
the nuts.
Figure 3 Installing the outer rails (HP 10000 Series Rack)
b.
Depending on the rack you are using, complete one of the
following tasks:
• For an HP 10000 Series Rack, install two #10-32 x 1/2-
inch Phillips panhead screws with captive star lock washers
and two #10 adapter washers in the upper and lower holes
on the right rail. Then, install two #10-32 x 1/2-inch Phillips
panhead screws with captive star lock washers and two
#10 adapter washers in the upper and lower holes on the
left rail. (See
Figure
Figure 4 Assembling the outer rails (HP 10000 Series Rack)
• For an HP System/e Rack, install two #10-32 x 1/2-inch
Phillips panhead screws with captive star lock washers and
two #10 alignment washers in the upper and lower holes
on the right rail. Then, install two #10-32 x 1/2-inch Phillips
panhead screws with captive star lock washers and two
#10 alignment washers in the upper and lower holes on
the left rail. (See
Figure
3. Do not tighten
4.)
Figure
5.)
Figure 5 Assembling the outer rails (HP System/e Rack)
5.
See
Table 2
to determine the screw type and the number of screws
required for your device.
CAUTION:
Use only the screws provided in the SAN Switch Rack
Mount Kit. Using other screws can cause damage to
internal components.
Table 2 Number of screws required to assemble the inner rails
Device model
SAN Switch 2/16
SAN Switch 2/8V
SAN Switch 2/16V
SAN Switch 2/32
4/8 SAN Switch
4/16 SAN Switch
SAN Switch 4/32
4/32B SAN Switch
MP Router
4/64 SAN Switch
400 MP Router
8/8 SAN Switch
8/24 SAN Switch
8/40 SAN Switch
8/80 SAN Switch
FCoE Converged Net-
work Switch
Encryption SAN
Switch
6.
Identify the screw holes to install the inner rails to your device:
• To attach the inner rails to the SAN Switch 2/16, SAN Switch
2/8V, or SAN Switch 2/16V, use the screw holes marked 8.
Page 4
#8-32 x 5/16-inch
#8-32 x 3/16-
screws
inch screws
Ten (five per rail)
N/A
Twelve (six
N/A
per rail)
Ten (five per rail)
N/A
Six (three per rail)
N/A
Six (three per rail)
N/A
Ten (five per rail)
N/A
Ten (five per rail)
N/A