Closed defect summary
If a device tries to login to an NPIV port using a port WWN, which
is already used by another device that has already logged in, the
switch simply drops the new login (FDISC) request instead of rejecting
it.
Incorrect FRU Update date is received for Brocade_Chassis class.
SetInstance call is failing for Brocade_Switch class.
Problem attempting to lock a port as an L_Port and configure the duplex
mode using the CLI.
Inconsistent support for switch service tag between CLI and Web Tools.
Port_scn removes logical paths from wrong port.
IOCTL not allowed: cmd 0x40040911, pid 11347 (ficonshow)
message seen on the console.
Validation of IP address to SetProperty/SetInstance for Com-
munityInfoSet on Brocade_Switch class is not present on higher
version (5.3,6.0).
nsd killed during overnight iSCSI blade slotpoweroff/on testing.
bladebeacon command should fail for core blades and switchshow
command should not show beacon status for core blades in the DC
Director chassis.
Even after deleting enabled DDset the DD members of that particular
ddset are still shown as enabled.
frureplace wwn command for DC Director platform takes over ten
minutes to complete.
Web Tools - USB admin always displays firmware build size incorrectly
as 32768 bytes whereas CLI shows the actual size.
CRC errors mismatch between porterrshow and portstatsshow
output.
Upon repeated reboots of the MP Router switch, ExternalInput
Oops message seen on the console, (stress-to-fail test).
FCIP testing with tape pipelining enabled results in failures.
Shortly after cfgdisable on an edge 4/256 SAN Director, got a
raslogd core dump.
Changing desired distance by issuing "portcfglongdistance
,slot/port> 1d 1 <distance>" from lower WWN switch often
causes E_Port to stuck at Unknown or send ECP failed and disabled.
With EX_Pports configured observed VERIFY on performing hafail-
over - Failed expression: 0, c2_debug.c, line = 7896 Call
back trace:Trace: bfe4241c <asic_val-
id_data+0x624/0x7a4 [condor2_module]> when EX_Ports
exist.
20
Solution
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0