v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Lit light path
diagnostics LED with
the system-error or
information LED also
lit
Description
SERVICE
There is a fault in the Remote
PROCESSOR BUS
Supervisor Adapter II SlimLine.
MEMORY
Memory failure.
Note: The error LED on the DIMM
is also lit.
DASD/RAID
A hard disk drive, integrated SAS
controller, or integrated RAID error
has occurred.
Notes:
1. The error LED on the failing
2. Check the BMC event log for a
FAN
A fan has failed or has been
removed.
Note: A failing fan can also cause
the TEMP LED to be lit.
PCI BUS
A PCI adapter has failed.
hard disk drive is also lit.
ServeRAID-8k or RAID error.
Action
1. Reseat the Remote Supervisor Adapter II SlimLine.
2. Update the firmware for the Remote Supervisor
Adapter II SlimLine (see the Problem
Determination and Service Guide on the IBM
System x Documentation CD).
3. Replace the Remote Supervisor Adapter II
SlimLine.
1. Remove the DIMM that has the lit error LED; then,
press the light path diagnostics button on the
DIMM to identify the failed DIMM.
2. Reseat the DIMM.
3. Replace the following components one at a time,
in the order shown, restarting the server each time:
a. DIMM
b. (Trained service technician only) System board
1. Reinstall the removed drive.
2. Reseat the following components:
a. Failing hard disk drive
b. SAS hard disk drive backplane
c. SAS signal and power cables
d. System board
e. ServeRAID-8k
3. Replace the components listed in step 2, one at a
time, in the order shown, restarting the server each
time.
1. Reinstall the removed fan.
2. If an individual fan LED is lit, replace the fan.
3. (Trained service technician only) Replace the
system board.
1. See the BMC log or the system-error log (see the
Problem Determination and Service Guide on the
IBM System x Documentation CD).
2. Reseat the failing adapter.
3. Replace the following components, one at a time,
in the order shown, restarting the server each time:
a. Failing adapter
b. (Trained service technician only) System board
Chapter 2. Installing optional devices
19

Advertisement