Final Checklist; Operation Checklist - GE PD968SPSS Installation Instructions Manual

30" drop-in electric range
Hide thumbs Also See for PD968SPSS:
Table of Contents

Advertisement

Available languages

Available languages

8 ­ R EPLACING THE OVEN DOOR (Continued)
3.­­­ O pen­the­door­as­far­as­it­will­open.­Push­the­
hinge­lock­up­against­the­front­frame­of­the­oven­
cavity,­to­the­locked­position.­Close­the­door.

FINAL CHECKLIST

9
­
­­
C heck­to­make­sure­the­circuit­breaker­is­closed­(Reset)­or­the­circuit­fuses­are­re­ p laced.
­­
B e­sure­power­is­in­service­to­the­building.
­­
C heck­to­be­sure­that­all­packing­materials­and­tape­have­been­re­ m oved.­Failure­to­remove­these­materials­
could­result­in­damage­to­the­appliance­once­the­appliance­has­been­turned­on­and­surface­elements­have­
heated

OPERATION CHECKLIST

10
­
­­
C heck­to­make­sure­the­Clock­display­is­energized.­If­a­series­of­horizontal­red­lines­appear­in­the­display,­
disconnect­power­immediately.­Recheck­the­range­wiring­con­ n ec­ t ions.­If­change­is­made­to­connections,­
retest­again.­If­no­change­is­required,­have­building­wiring­checked­for­proper­connections­and­voltage.­It­is­
recommended­that­the­clock­be­changed­if­the­red­lines­appear.
­­
P ush­down­and­turn­any­one­of­the­four­surface­knobs­to­"MED"­setting­to­observe­that­the­element­glows­
within­15­seconds.­Turn­the­knob­off­when­glow­is­detected.­If­the­glow­is­not­de­ t ect­ e d­within­the­time­limit,­
recheck­the­range­wiring­connections.­If­change­is­required,­retest­again.­If­no­change­is­required,­have­
building­wiring­checked­for­proper­connections­and­voltage.
Installation­Instructions
Notch­of­Hinge­
Securely­Fitted­
into­Bottom­of­
Hinge­Slot
10
Hinge­in­Locked­
Position