Panasonic TH32LRU20 - HOSPITALITY LCD HDTV Operating Instructions Manual page 34

Hospitality lcd hdtv
Hide thumbs Also See for TH32LRU20 - HOSPITALITY LCD HDTV:
Table of Contents

Advertisement

Technical Information
A standard 6 pin RJ-11C connector is used to provide a connection between the MTI equipment and the TV set. Both the MTI terminal and
TV are equipped with FCC-66 style (RJ-11C) jacks. Each of these jacks shall accept a 6 contact plug Molex P/N 90075-0007 or equivalent.
External TA
Multiple Television Interface(MTI)
Pin layout for RJ-11C terminal
1 2 3 4 5 6
Internal TA
Compatible with LodgeNet game controller(DATA)
PC Control of the TV
The TV can be controlled by a personal computer when
connected through an RS232C cable (not supplied).
The computer will require software which allows sending
and receiving of control data through its SERIAL port.
Please see required parameters and commands below.
Pin layout and signal name for SERIAL CTRL terminal
Basic format for control data
The transmission of control data from the external device starts with a STX signal, followed by the command, the parameters,
and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent.
STX
Start (02 h): 1 byte
Notes
With standby mode, this TV responds to "PON" and "QPW" commands only.
Wait for the response of the first command to come from this unit before sending the next command.
If multiple commands are transmitted, be sure to keep intervals of 250msec. Send the command again when the call back
command is unusual.
If an incorrect command is sent by mistake, this TV will send an "ER401" or "ER402" command back to the computer.
This TV does not respond for 15 seconds when "PON" or "POF" commands are transmitted.
Send "EXT" commands before sending "IMS:**" commands.
34
DATA/MTI (RJ11) terminal connection
Interface signals on the interface
TV Connector Pin
1
2
3
4
5
6
SERIAL CRTL (RS232C (M3)) terminal connection
Tx
GND
Rx
Colon and Parameter are only sent when necessary
C1
C2
C3
:
Command: 3 byte (fixed)
Colon: 1 byte
Signal
Clock
MTI Data
Open
TV Data
Ground
IR Data
Communication parameters
Signal level
Synchronization method
Baud rate
Character length
Stop bit
Flow control
TV set
GND
Tx_TV (Transmission of TV side)
Rx_TV (Reception of TV side)
P1
P2
P3
Parameter: 5 bytes maximum (Length depends on Command)
* Please see p. 35 regarding Commands and Parameters.
(Continued)
MTI terminal
Signal source
Connector Pin
6
5
4
3
2
1
RS-232C compliant
Parity
P4
P5
TV
MTI
N/C
TV
Common
TV
Asynchronous
9600 bps
None
8 bits
1 bit
-
End (03 h): 1 byte
ETX

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-42lru20Th-37lru20

Table of Contents