v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
I9990305
An operating system was not found.
I9990650
AC power has been restored.
76
IBM System x3500 Type 7977: Installation Guide
Action
1. Make sure that a bootable operating system is
installed.
2. Run the hard disk drive diagnostic tests.
3. Reseat the following components:
a. Hard disk drive
b. SAS hard disk drive backplane and cables
c. DVD drive and cables
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Hard disk drive
b. SAS hard disk drive backplane and cables
c. DVD drive and cables
d. (Trained service technician only) System
board
1. Check the power cables.
2. Check for interruption of the power supply (see
the Problem Determination and Service Guide on
the IBM System x Documentation CD for
information on the power-supply LEDs).
3. Reseat the following components:
a. Power supply
b. (Trained service technician only) Power
backplane
4. Replace the components listed in step 3, one at a
time, in the order shown, restarting the server
each time.