GE DVLR223W Installation Instructions Manual

Installation instructions

Advertisement

Quick Links

Installation
Instructions
If you have any questions, call 1-800-GECARES (US) or 1-800-361-3400 (Canada)

BEFORE YOU BEGIN

Read these instructions completely and carefully.
IMPORTANT -
instructions for local inspector's use.
IMPORTANT -
governing codes and ordinances.
• Note to Installer - Be sure to leave these instructions with
the customer.
• Note to Customer - Keep these instructions with your Use
and Care Book for future reference.
• This dryer must be exhausted to the outdoors.
• Before the old dryer is removed from service or discarded,
remove the dryer door.
• Service Information and the wiring diagram are located in
the control console.
• Do not allow children on or in the appliance. Close
supervision of children is necessary when the appliance is
used near children.
TOOLS YOU WILL NEED
10" ADJUSTABLE WRENCHES (2)
8" PIPE WRENCHE
Step 1 Verify Your Gas Installation (see section 2).
Step 2 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 3 Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications.(see section 6)
Step 4 Remove the Foam Shipping Pads (see section 1).
Step 5 Move the Dryer to the Desired Location.
Step 6 Level Your Dryer (see section 8).
Step 7 Connect the Gas Supply (see section 3) and check
for leaks (see section 4).
or Visit our Web site at: www. GEAppliances.com
Save these
Observe all
MATERIALS YOU WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
LEVEL

FOR YOUR SAFETY:

WARNING
• Use only rigid metal or flexible metal 4-in. diameter
ductwork for exhausting to the outdoors. Never use
plastic or other combustible easy-to-puncture ductwork.
• This appliance must be properly grounded and installed
as described in these instructions.
• Do not install or store appliance in an area where it
will be exposed to water and/or weather.
• The National Fuel Gas Code restricts installations of
gas appliances in garages. They must be 18 in. off the
ground and protected by a barrier from vehicles.
• Install the dryer where the temperature is above 50ºF
for satisfactory operation of the dryer control system.
NOTE: Installation and service of this dryer must
be performed by a qualified installer, service
agency, or the gas supplier.
4" DIA. METAL DUCT
4" DIA. METAL ELBOW
(RECOMMENDED)
PIPE COMPOUND
4" DIA. FLEXIBLE METAL DUCT
FLEXIBLE GAS LINE CONNECTOR
Step 8 Connect the External Exhaust (see section 7).
Step 9 Connect the Power Supply (see section 5).
Step 10 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation see section 9.
For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured Home see section 11.

Gas Dryer

38
DUCT
CLAMPS (2)
(IF NEEDED)
GLOVES
SAFETY GLASSES
SOAP SOLUTION
FOR LEAK DETECTION
EXHAUST HOOD
DUCT TAPE

Advertisement

Table of Contents
loading

Summary of Contents for GE DVLR223W

  • Page 1: Gas Dryer

    Gas Dryer Installation Instructions If you have any questions, call 1-800-GECARES (US) or 1-800-361-3400 (Canada) or Visit our Web site at: www. GEAppliances.com BEFORE YOU BEGIN FOR YOUR SAFETY: Read these instructions completely and carefully. WARNING IMPORTANT - • Use only rigid metal or flexible metal 4-in. diameter •...
  • Page 2: Gas Requirements

    Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration must be given to provide adequate clearance for proper operation and service. 1 PREPARING FOR INSTALLATION TILT THE DRYER SIDEWAYS OF NEW DRYER...
  • Page 3 Installation Instructions 3 RECONNECTING GAS APPLY PIPE COMPOUND ADAPTER TO ALL MALE THREADS. 1/8" NPT PIPE PLUG FOR NEW METAL CHECKING GAS FLEXIBLE GAS INLET PRESSURE LINE CONNECTOR SHUT-OFF ADAPTER VALVE 3/8" NPT ELBOW PIPE SIZE ITEMS NOT SUPPLIED AT LEAST 1/2" TIGHTEN ALL CONNECTIONS USING TWO ADJUSTABLE WRENCHES.
  • Page 4: Electrical Connection Information

    Installation Instructions 5 ELECTRICAL CONNECTION 6 EXHAUST INFORMATION INFORMATION WARNING - USE ONLY METAL 4-IN. DUCT. WARNING - TO REDUCE THE RISK OF DO NOT USE DUCT LONGER THAN SPECIFIED FIRE, ELECTRICAL SHOCK, AND PERSONAL IN THE EXHAUST LENGTH TABLE. INJURY: Exhaust longer than specified will: •...
  • Page 5: Exhaust Connection

    Installation Instructions 7 EXHAUST CONNECTION WARNING - TO REDUCE THE RISK OF FIRE OR PERSONAL INJURY: • This dryer must be exhausted to the outdoors. FOR STRAIGHT • Use only metal duct. LINE INSTALLATION, • Do not terminate exhaust in a chimney, any gas vent, CONNECT THE under an enclosed floor (crawl space), or into an attic.
  • Page 6: Alcove Or Closet Installation

    Installation Instructions USING FLEXIBLE METAL DUCTS 9 ALCOVE OR CLOSET INSTALLATION If rigid all-metal duct cannot be used, then flexible all-metal • If your dryer is approved for installation in an alcove or venting can be used, but it will reduce the maximum closet, it will be stated on a label on the dryer back.
  • Page 7 Installation Instructions 12 DRYER EXHAUST TO LEFT OR ADDING NEW DUCT BOTTOM OF CABINET FIXING HOLE PORTION "A" WARNING - PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE CABINET. LEFT SIDE REMOVE EXHAUST SCREW Reconnect the cut portion (A) of the duct to the blower AND SAVE.
  • Page 8 Installation Instructions 13 CHANGING DIRECTION OF ADDING ELBOW FOR EXHAUST DOOR OPENING THROUGH BOTTOM OF CABINET • Insert the elbow through the rear opening and connect it to the dryer internal duct. • Apply duct tape on the joint between the dryer internal duct and elbow, as shown on page 7.

This manual is also suitable for: