-1
-1
-2
28
1.
Open the top plate.
2.
Remove Cover Cabinet.
3.
Disconnect the door lamp and electro
sensor connector.
4.
Remove 4 screws.
5.
Disassemble the Tub Drum [Front].
1.
Open the top plate.
2.
Remove the Cover Cabinet and
Tub drum [front].
3.
Disengage belt from motor and idler pulleys.
4.
Carefully remove Drum out through front of dryer.
1.
Open the door.
2.
Remove the screw holding the drum lamp shield
in place.
3.
Slide the shield up and remove.
4.
Remove the bulb and replace with a 15 watt,
120 volt candelabra-base bulb.
5.
Replace the lamp shield and screw.