Dell PowerEdge 1955 Configuration Manual page 27

Configuration guide
Hide thumbs Also See for PowerEdge 1955:
Table of Contents

Advertisement

Available languages

Available languages

Configuring a Port on a Cisco Catalyst Blade Switch 3030 Switch Module
The following is an example of how to configure a port to operate at 100 Mbps and half duplex.
(Note that you configure the switch using the DRAC/MC module, rather than the external console
port on the switch module itself.)
1 Log on to the DRAC/MC Telnet or serial interface.
2 Enter the following command to enter privileged EXEC mode:
switch-1> enable
3 Change to global configuration mode:
switch-1# configure
4 Select a particular port and change to interface configuration mode:
switch-1(config)# interface interface-id
5 Set the port speed to 100 Mbps:
switch-1(config-if)# speed 100
6 Set the port to operate at half duplex:
switch-1(config-if)# duplex half
7 Return to privileged EXEC mode:
switch-1(config-if)# end
8 Exit privileged EXEC mode:
switch-1# disable
9 End the configuration session:
switch-1> logout
Configuring the PowerConnect 5316M Ethernet Switch Module
The PowerConnect 5316M Ethernet switch module is a 16-port switch with 6 uplinks and
10 downlinks:
The 6 uplinks connect to the external Ethernet network and operate at 10/100/1000 Mb.
The downlinks connect to the embedded Ethernet controller on the server modules and
operate at 1000 Mb only.
For additional information about the PowerConnect 5316M Ethernet switch module, see the
documentation that shipped with the module or on support.dell.com.
interoperability configurations, see the Link Aggregation Interoperability of the Dell PowerConnect
5316M with Cisco IOS or Cisco CatOS-Based Switches engineering brief on the switch module's
page on www.dell.com.
or detailed information on
F
General System Configuration
25

Advertisement

Table of Contents
loading

Table of Contents