SERVICE WARNING LIGHT (All Models except WB5E)
All models except WB5E have this facility. This light is designed to help you
discover the cause of any malfunction. If the circuit senses a problem, the
service light will flash a number of times and then pause and repeat this
sequence. Count the number of flashes between pauses and refer to the table
on the back cover. Some serious service problems will disable the boiler whist
less serious ones will allow you to continue to operate until a convenient time
arises for the fault to be rectified.
NUMBER OF
FLASHES
BETWEEN
PAUSES
1 Constant
Water level sensor has scaled up
at normal level and machine has
filled to a higher level
2
Operating level sensor has been
detected but lower level sensor
has not
3
Overfill level sensor has been
detected but other sensors have
not
4
Danger level sensor has been
detected and machine functions
have been shut down
5
Thermistor or potentiometer have
failed
6
Boiler has failed to fill in the
allotted time. Possible causes :-
1. Water supply turned off.
2. Water inlet valve has failed.
3. Blockage in water inlet pipe.
4. Pipe connecting inlet valve to
5. Bottom sensor is scaled up
7
The temperature sensor
(thermistor) has become
disconnected or the heating
element(s) have failed.
8 or 9
Fault on temperature sensor
(thermistor).
10
Heating element(s) faulty .
The water supply has been
11
interrupted and the level has
MEANING
boiler has become detached.
Clean Sensing Probes
Clean Sensing Probes
Clean Sensing Probes
Clean Sensing Probes
Call service department on
01704 502911
Quoting the Serial Number
Check water supply
If in order call Instanta
service department quoting
the Serial Number
Call service department on
01704 502911
Quoting the Serial Number
Call service department on
01704 502911
Quoting the Serial Number
Call service department on
01704 502911
Quoting the Serial Number
Check water supply
12