The WUVCLP light package should only be installed by a trained heating and
air conditioning technician. These instructions are not intended to be a step-
by-step procedure that the mechanically inclined owner can use to install the
WUVCLP light package. Rather these instructions serve as a guide to the
technician installing the WUVCLP light package
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION
LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
SAFETY CONSIDERATIONS
WARNING: Never expose eyes or skin to UVC light from any source.
• Looking directly at the UVC light may cause permanent eye damage or blindness.
• Never operate the UV Air Purifying System out of the plenum.
WARNING: UV light will break down plastic materials not rated for UV exposure:
(Examples: wire insulation, flex duct, drain pans and humidifiers)
• The unit must be mounted at least 30" from the above stated type of materials.
• If it is necessary to mount the unit in direct line of site of these types of materials, they must be
shielded with aluminum foil, aluminum foil tape, or sheet metal.
Model: WUVCLP-A & WUVCLP-C
DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.
Bard Manufacturing Company
Bryan, Ohio 43516
Since 1914...Moving ahead, just as planned.
Manual No.:
2100-432
Supercedes:
File:
Vol III Tab 19
Date:
2/14/03

Advertisement

Table of Contents
loading

Summary of Contents for Field Controls 46441700

  • Page 1 WALL MOUNT SERIES UV LIGHT PACKAGE Model: WUVCLP-A & WUVCLP-C The WUVCLP light package should only be installed by a trained heating and air conditioning technician. These instructions are not intended to be a step- by-step procedure that the mechanically inclined owner can use to install the WUVCLP light package.
  • Page 2: Table Of Contents

    Table of Contents Page No. General Unpacking ....................Page 1 Description ....................Page 1 Installation Basic Installation ..................Page 3 Wiring 230 Volt Single Phase and Three Phase Units Only ......Page 7 460 Volt Three Phase Units Only ............Page 8 Checkout ....................Page 10 Parts List ......................Page 10 Figures Figure 1...
  • Page 3: General

    GENERAL This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition. NPACKING The WUVCLP light package is shipped in one carton, which contains the electrical wires, UV light assembly, UV light bulb, 4 mounting screws, alcohol wipe, transformer for the 460 volt models, and installation instructions.
  • Page 4 Compatibility Chart: Table 1 WA18*-A WH18*-A WH26*-A SH26*-A WA24*-A WH24*-A WH31*-A SH31*-A WA30*-A WH30*-A WH38*-A SH37*-A WUVCLP-A WA37*-A WH36*-A WH43*-A SH43*-A WA42*-A WH42*-A WH49*-A SH49*-A WA48*-A WH48*-A WH61*-A SH61*-A WA60*-A WH60*-A WA70*-A WA24*-B WH18*-B WH26*-B SH26*-B WA30*-B WH24*-B WH31*-B SH31*-B WA37*-B WH30*-B WH38*-B SH37*-B...
  • Page 5: Installation

    INSTALLATION ASIC NSTALLATION Before doing any service work, the unit disconnect must be turned off and locked to prevent injury or death due to electrical shock or contact with moving parts. The thermostat must also be turned off. Unpack the ultraviolet light kit, accessories, and Installation Instructions. On the top of the UV light kit there is an adjustable bracket on the left and right side of the housing (see figure 1).
  • Page 6 Remove the exterior blower access panel from the wall mount unit and set it aside. (See Figure 2) Using the top screw hole for the blower door panel as a starting point, drill two ¼ inch holes on each side of the unit to secure the mounting brackets of the WUVCLP. See Figure 3 for hole locations.
  • Page 7: Wiring

    Slide the left bracket tight against the left side of the unit. Insert two self drilling screws on the left side of the unit and into the left side mounting bracket of the WUVCLP light assembly. Use the pilot holes mounting brackets alignment.
  • Page 8: 460 Volt Three Phase Units Only

    Remove outer and inner control panel covers. Install the 3 pin accessory plug from the parts bag into the control panel if not already equipped. See figure 7A for side installation on the 5 or 6 ton cabinet size. See figure 7B for back installation on the 2 and 3 ton cabinet size.
  • Page 9 Remove outer and inner control panel covers. Install the 3 pin accessory plug from the parts bag into the control panel if not already equipped. See figure 6A for side installation the 5 or 6 ton cabinet size. See figure 6B for back installation on the 2 and 3 ton cabinet size.
  • Page 10: Parts List

    WARNING: Hazard of Electric Shock • Electric shock can cause serious injury or death • Disconnect power before servicing the light WARNING: Hazard of Ultraviolet Type C Light • Looking directly at the UVC light may cause permanent eye damage or blindness. •...
  • Page 11 IV. WIRING DIAGRAM Page 11...