24 VAC SYSTEM CONTROL KIT
Model: CK-92F and CK-92FG
Designed for use with the SWG Series Power Venter for controlling Natural
Gas or L.P. Gas appliances with a 24 VAC Gas Valve and a 30-millivolt
controlled Natural or L.P. Gas Water Heater.
I
:
TEMS INCLUDED IN KIT
1) Junction box with mounted pressure switch and post purge timer
1) Fan control gas pressure switch with built in post purge option
1) 2 ft. length of 1/4 inch aluminum tubing
1) 1/8" NPT x 3 inch pipe nipple
1) 1/8" NPT x 1/4 inch OD tubing elbow
1) 1/8" NPT pipe tee
1) TCA-1 Thermocouple Adaptor (CK-92F)
1) TCA-2 Left Handed Thermocouple Adaptor (CK-92FG)
1) 6 ft. length of 12-2 wire
1) 8 inch jumper wire
2) Flexible conduit connector
2) GSK-3 Spillage Switch
1) 1/4 inch tubing connector
THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT
DO NOT DESTROY

Advertisement

loading

Summary of Contents for Field Controls 46285400

  • Page 1 24 VAC SYSTEM CONTROL KIT Model: CK-92F and CK-92FG Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances with a 24 VAC Gas Valve and a 30-millivolt controlled Natural or L.P. Gas Water Heater. TEMS INCLUDED IN KIT 1) Junction box with mounted pressure switch and post purge timer 1) Fan control gas pressure switch with built in post purge option...
  • Page 2: Installation

    INSTALLATION OUNTING UNCTION The junction box can be mounted at the venter or remotely mounted away from the venter. (See Figure 1 & Figure 2) 1. Remove one of the knockouts from the side of the junction box where the pressure switch is mounted.
  • Page 3 ADJUSTMENTS ROVING WITCH DJUSTMENTS After proper air flow is established, the pressure switch adjustment is made by turning the pressure switch adjustment screw clockwise (See Figure 4) until burner operation stops. Turn the adjustment screw counterclockwise until burner ignites. Turn the adjustment screw an additional 1/4 to 3/4 turn counterclockwise to ensure adequate switch adjustment.
  • Page 4 NOTE: Draft spillage switches should be mounted 90 degrees apart, and mounted opposite from the vent outlet direction. (See Figure 9) 3. Mount the two spillage switches onto the draft hood and connect inside terminals of switches with jumper wire. Connect outside terminals to lead wires which are connected to the thermocouple junction block.
  • Page 5 Diagram B L1 to 1 on post purge timer T2 to timer relay base M to 3 on post purge timer T3 to N/O on pressure switch T1 to common on pressure switch Timer base to common on pressure switch OLTAGE IRING NSTRUCTIONS...
  • Page 6 SYSTEM CONTROL CHECK OUT PROCEDURES 1. For furnaces or boilers, adjust the thermostat to call for heat and observe the power venting system for proper operation sequence. (Repeat if necessary) a. Thermostat calls for heat. b. Relay is energized and venter motor starts. c.
  • Page 7 INSTALLATION INFORMATION CK-92F/CK-92FG MODEL NO.:____________________________________________________________ INSTALLER'S NAME:_____________________________________________________ INSTALLER'S COMPANY: _________________________________________________ INSTALLER'S PHONE NO.: ________________________________________________ DATE OF INSTALLATION:_________________________________________________ Page 7...
  • Page 8 Page 8 P/N 46285400 Rev C 10/03...