Summary of Contents for Dimplex LA 12 PS
Page 1
LA 9 PS LA 12 PS LA 18 PS Luft/Wasser- Wärmepumpe für Außenaufstellung Bestell-Nr. / Order no. / N de commande : 452149.66.19 Montage- und Gebrauchsanweisung Installation and Operating Instructions Instructions d’installation et d’utilisation Air-to-Water Heat Pump for Outdoor Installation Pompe à...
Please Read Immediately 1.1 Important Information ATTENTION! Any work on the heat pump may only be performed by authorised and qualified after-sales service technicians. ATTENTION! The device is not suitable for operation with a frequency converter. ATTENTION! Never install the device in rooms in which there are any permanent ignition sources.
Purpose of the Heat Pump 2.1 Application The air-to-water heat pump is designed for use in existing or newly built heating systems. It is designed exclusively for heating domestic hot water and heating water! The heat pump is suitable for mono energy and bivalent opera- tion down to an external temperature of -20 °C.
The devices LA 12PS and LA 18PS are packaged with transport pipes on the wooden pallets. These pipes can be inserted using the boreholes of the heat pump base frame (they are sealed with...
5.2 Condensed Water Pipe Condensed water that forms during operation must be drained off frost-free. The heat pump must be mounted on a level plane to guarantee proper drainage. The condensed water pipe must have a minimum diameter of 50 mm and should be fed frost-free into a sewer.
The antifreeze function of the heat pump con- troller is active whenever the controller and the heat circulating pump are ready for operation. If the heat pump is taken out of service or in the event of a power failure, the system has to be drained, and if required, blown out, at three locations (see illus- tration).
To prevent acidic cleaning agents from entering the heating sys- tem circuit, we recommend connecting the flushing device di- rectly to the flow and return flow of the liquifier of the heat pump. It is important that the system be thoroughly flushed using appro- priate neutralising agents to prevent any damage from being caused by cleaning agent residue remaining in the system.
ATTENTION! Any work on the heat pump may only be performed by authorised and qualified after-sales service technicians. Anyone carrying out work on the refrigerating circuit must be cer- tified to safely handle inflammable refrigerants or be supervised by a person having such certification.
The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature and 55 °C heating water flow temperature. 3. See CE declaration of conformity 4. The heat circulating pump and the heat pump controller must always be ready for operation. LA 9PS IP24...
Flow sensor, heating water Terminal strip: Incoming supply to the load Terminal strip: Internal wiring Plug connector, control line/heat pump Plug connector, control line/heat pump controller Four-way valve Chauffage à carter compresseur Pressostat fin de dégivrage Chauffage à couronne perforée ventilateur...
4.2 Monoenergetische Anlage und Warmwasserbereitung / Mono Energy System and Domestic Hot Water Preparation / Installation monoénergétique et production d’eau chaude A-XXI...
Shutoff valve with check valve Heat consumer Four-way mixer Temperature sensor Flexible connection hose Heat pump Buffer tank Heat pump controller Electrical distribution system Hot water cylinder Boiler Supplementary heating Heat circulating pump Hot water circulating pump Heat pump controller...
5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité A-XXIV...
Page 35
Glen Dimplex Deutschland GmbH Irrtümer und Änderungen vorbehalten. Geschäftsbereich Dimplex Subject to alterations and errors. Am Goldenen Feld 18 Sous réserve d’erreurs et modifications. D-95326 Kulmbach +49 (0) 9221 709 565 www.dimplex.de...