Dimplex DXUF20T Installation And Operating Instructions

Dimplex fan heater dxuf20t & dxuf30t installation and operating instructions

Advertisement

Quick Links

Fan Heaters
Model(s) : DXUF20T & DXUF30T
Dimensions
(millimetres)
Model(s)
Specification
DXUF20T
2.0kW Thermostat & Switch
DXUF30T
3.0kW Thermostat & Switch
IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
IMPORTANT SAFETY ADVICE
READ THESE INSTRUCTIONS BEFORE USE.
DO NOT use the heater on deep pile carpets or the long hair
type of rugs, or less than 750mm (30") away from any
overhanging surface. Keep combustible materials such as
drapes and other furnishings clear from the front, sides
and rear of the heater. Do not use heater to dry your laundry.
DO NOT use the heater in the immediate surroundings of a
bath, a shower or a swimming pool.
DO NOT place the heater directly below a fixed socket outlet.
The socket-outlet must be accessible at all times to enable
the mains plug to be disconnected as quickly as possible.
DO NOT COVER or obstruct the air inlet and outlet openings
in any way.
The heater must be on a flat stable surface when in use.
DO NOT operate the heater with the mains lead overhanging
the front outlet grille.
NEVER leave the heater unattended when it is used by or
near the aged, infirm person's or children.
The heater carries the Warning symbol indicating that
it must not be covered.
The instruction leaflet belongs to the appliance and must
be kept in a safe place. If changing owners, the leaflet
must be surrendered to the new owner.
IMPORTANT – If the mains lead of this appliance is damaged,
it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a
hazard.
WARNING: In order to avoid a hazard due to inadvertent
resetting of the thermal cut-out, this appliance must not be
supplied through an external switching device, such as a
timer, or connected to a circuit that is regularly switched on
and off by the utility.

Electrical connection

This heater must be used on an A.C
marked on the heater must correspond to the supply voltage. This heater
is fitted with a plug incorporating a 13 amp fuse. When replacing the
fuse, a 13 amp fuse approved by ASTA to BS 1362 must be used.
If the plug is not suitable for the socket outlets in your home, the plug
must be cut off and an appropriate one fitted. A plug cut off from a
mains lead will give a shock hazard if inserted into a 13 amp socket
elsewhere in the house. To avoid this, it should be disposed of
immediately.
H
W
D
236
242
175
.~
supply only and the voltage
Installation and Operating Instructions
(IP20)
(see Fig. 3)
NOTE: The fuse cover of a non-rewirable plug must be refitted when
changing the fuse. Should the cover become lost, the plug must not be
used until the correct replacement fuse cover is obtained from your
supplier or by contacting our customer helpline.
IMPORTANT : The wires in this mains lead are coloured in accordance
with the following code :
BLUE :
BROWN :
As the colours of the wires in the mains lead may not correspond with
the coloured markings in your plug, proceed as follows :
Connect the BROWN wire to the terminal marked 'L' or coloured RED.
Connect the BLUE wire to the terminal marked 'N' or coloured BLACK.
Note : 'L' or 'N' must not be connected to the EARTH terminal marked
'E' or
or coloured GREEN or GREEN AND YELLOW.
If in doubt, consult your electrician.
Using the Heater
- see Fig. 2
Heat Control
Fig. 2
see Fig. 3
Thermostat Control -
*
Fig. 3
The heater will now cycle on and off to maintain your selected room
temperature. An audible click may be heard when the thermostat
operates - this is normal.
Note : If the heater does not come on when the thermostat is at a low
setting, this is normally because the room is warmer than the thermostat
setting and is not a fault.
* When the heat control is set to '
control to maximum.
Position '
' will turn the heater on and off to maintain a temperature of
*
approximately 5°C.
08/35113/0
(see Fig. 2)
Fig. 1
NEUTRAL
LIVE
-
OFF
-
Cool Blow*
-
Half heat
-
Full heat
The heat output is controlled by the
thermostat, according to the room
temperature.
Turn the thermostat knob fully clockwise
to maximum setting initially. When the
room is warm enough, reduce the setting
slowly until the heater just clicks off.
' for cool blow, set the thermostat
Issue 0

Advertisement

loading

Summary of Contents for Dimplex DXUF20T

  • Page 1: Electrical Connection

    Fan Heaters Model(s) : DXUF20T & DXUF30T Dimensions (millimetres) Model(s) Specification DXUF20T 2.0kW Thermostat & Switch DXUF30T 3.0kW Thermostat & Switch IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE IMPORTANT SAFETY ADVICE READ THESE INSTRUCTIONS BEFORE USE.
  • Page 2 Hampshire. SO30 2DF [c] Glen Dimplex UK Limited All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited. After Sales Service Your product is guaranteed for three years from the date of purchase.