Linksys SFE2000P - Managed Ethernet Switch Installation And Administration Manual

Cisco rps1000 380w redundant power supply administration guide
Hide thumbs Also See for SFE2000P - Managed Ethernet Switch:

Advertisement

Linksys One Business Series RPS1000
Installation and Administration Guide
March 2007
Linksys One Business Series 380W Redundant
Power Supply
Model RPS1000

Advertisement

Table of Contents
loading

Summary of Contents for Linksys SFE2000P - Managed Ethernet Switch

  • Page 1 Linksys One Business Series RPS1000 Installation and Administration Guide March 2007 Linksys One Business Series 380W Redundant Power Supply Model RPS1000...
  • Page 2: Document Revision History

    Specifications are subject to change without notice. Linksys, the Cisco Systems logo, the Linksys Logo, and the Linksys One logo are registered trademarks of Cisco Systems, Inc. All other trademarks mentioned in this document are the property of their respective owners.
  • Page 3: Table Of Contents

    Appendix B: Troubleshooting ....22 Appendix C: Linksys Contact Information ... . 23 Appendix D: Connector and Cable Specifications ..25...
  • Page 4: Chapter 1: Preface

    Purpose This guide documents the hardware features of the Linksys Business Series 380W Redundant Power Supply Unit (RPS1000). It describes the physical and performance characteristics of the RPS1000, explains how to install the RPS1000, and provides troubleshooting information.
  • Page 5 Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration • SGE2000 Gigabit Ethernet Switch Quick Installation Guide • SGE2000P Gigabit Ethernet Switch Quick Installation Guide • SFE2000/SFE2000P Fast Ethernet Administration Guide • SFE2000/SFE2000P Fast Ethernet Reference Guide • SGE2000/SGE2000P Gigabit Ethernet Administration Guide •...
  • Page 6: Chapter 2: Product Overview

    We recommend using an uninterruptable power system (UPS) as protection against power outages. The RPS1000 was designed to support specific Linksys Business Series products. Connectors are not interchangeable. Consult your switch documentation to determine if it supports the RPS1000 product.
  • Page 7 Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration The RPS1000 has these features: • Six output channels to support multiple devices • RPS1000 status information available through the network management application on the device • Front-panel LEDs to show status for each output channel, internal power supplies, fans, and temperature •...
  • Page 8: Front-Panel Description

    Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration Front-Panel Description The RPS1000 front panel includes the status LEDs for the RPS1000 and a STBY/ACTIVE button. LEDs The LEDs display the status of the RPS1000 and show whether the RPS1000 is powering a connected device.
  • Page 9: Stby/Active Button

    Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration Green Amber The fan is The fan is not operating RPS1000 is running. properly. not powered STBY/ACTIVE Button Color DC Output Status No device is connected to the output connector. A device is connected to the output connector. Green The RPS1000 is unavailable to the connected device.
  • Page 10: Rear-Panel Description

    Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration When you want to connect additional devices, press the STBY/ACTIVE button to place the RPS1000 in standby mode. The STBY/ACTIVE LED flashes amber. When you have connected and powered up all devices, press the STBY/ACTIVE button again to put the RPS1000 into active mode. NOTE: When the RPS1000 is in standby mode, all of the DC Output LEDs are amber.
  • Page 11: Deployment Strategies

    You can deploy the RPS1000 in a variety of situations with mission-critical applications. One application might be in a voice and data network in which Linksys Business Series switches are connected to Linksys Business Series IP phones and PCs. Connecting an RPS1000 to the switches can prevent voice network failures that are caused by switch failures.
  • Page 12 Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration When the network supports mission-critical applications that require one-to-one redundancy, an RPS1000 is connected to each supported device to ensure that each switch is always supported. This one-to-one redundant configuration is shown below. Ethernet Switches RPS1000 RPS Units Chapter 2: Product Overview...
  • Page 13: Chapter 3: Installation

    Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration Installation This chapter describes how to install and connect the RPS1000 and includes these topics: • Preparing for Installation • Installing the Switch • Connecting the RPS1000 Preparing for Installation Read these sections and perform the procedures in the order that they are presented: •...
  • Page 14: Warnings

    Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration Warnings. WARNING: To prevent the switch from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 113°F (45°C). To prevent airflow restriction, allow at least 3 inches (7.6 cm) of clearance around the ventilation openings.
  • Page 15 Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration WARNING: This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. WARNING: The plug-socket combination must be accessible at all times, because it serves as the main disconnecting device.
  • Page 16: Site Requirements

    Replace all packing material into the shipping container and save it. These items are shipped: • The RPS1000 • This Linksys Business Series RPS1000 Redundant Power System Hardware Installation Guide • Product Registration Card • AC power cord •...
  • Page 17: Installing The Switch

    3. Place the RPS1000 chassis on an appropriate table, shelf, or desktop. NOTE: If you have questions or need assistance, see the Appendix C, "Linksys Contact Information," section. Rack-Mounting To install the chassis in a 19-inch or 24-inch rack, follow the instructions described in these procedures.
  • Page 18: Planning Your Rack-Mount Installation

    Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration Planning Your Rack-Mount Installation WARNING: To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: •...
  • Page 19: Attaching The Brackets To The Rps1000

    Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration Attaching the Brackets to the RPS1000 The bracket orientation and the screws that you use depend on whether you are attaching the brackets for a 19-inch or a 24-inch rack. Use two of the supplied screws to attach each bracket, according to the following guidelines: •...
  • Page 20: Mounting The Rps1000 In A Rack

    Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration Mounting the RPS1000 in a Rack After the brackets are attached to the RPS1000, use the four supplied number-12 Phillips machine screws to securely attach the brackets to the rack, as shown below. Connecting the RPS1000 CAUTION: Make sure that the RPS1000 is either in standby mode or that the RPS1000 AC power is...
  • Page 21 Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration NOTE: The switch might restart when it changes from RPS1000 power to its own internal power. This situation might occur after the power supply on a switch fails, the RPS1000 takes over, and the switch reverts to its own power.
  • Page 22 Chapter RPS1000—Business Series 380W RPS Unit Installation & Administration 5. Connect all supported devices to an AC power source. NOTE: The RPS1000 is designed to provide backup for internal power supply failures of connected device power supplies. It is not designed to act as a backup power source that protects against losses of power due to external power outages.
  • Page 23: Appendix A: Technical Specifications

    Appendix RPS1000—Business Series 380W RPS Unit Installation & Administration Technical Specifications The following table lists the technical specifications for the RPS1000. Environmental Ranges Operating temperature 32 to 113°F (0 to 45°C) Storage temperature –4 to 149°F (–20 to 65°C) Operating humidity 10 to 85% (noncondensing) Storage humidity 5 to 95% (noncondensing)
  • Page 24 Appendix RPS1000—Business Series 380W RPS Unit Installation & Administration AS/NZS 3260, TS001 EN 55024: 1998 (CISPR24) VCCI Class A CCC approval pending AS/NZS 3548 Class A CLEI code CNS 13438 Class A Appendix A:...
  • Page 25: Appendix B: Troubleshooting

    Appendix RPS1000—Business Series 380W RPS Unit Installation & Administration Troubleshooting The RPS1000 is not repairable in the field. The following table shows the appropriate action to take for specific LED indications. Symptom Condition Action STBY/ACTIVE LED is Press the STBY/ACTIVE button to put the The RPS1000 is in standby mode.
  • Page 26: Appendix C: Linksys Contact Information

    Linksys Contact Information Need to contact Linksys? Visit us online for information on the latest products and updates to your existing products at: http://www.linksys.com/international If you experience problems with any Linksys product, you can e-mail us at: In Europe E-mail Address Austria support.at@linksys.com...
  • Page 27 Appendix RPS1000—Business Series 380W RPS Unit Installation & Administration Outside of Europe E-mail Address Asia Pacific asiasupport@linksys.com (English only) support.portuguese@linksys.com or Latin America support.spanish@linksys.com Middle East & Africa support.mea@linksys.com (English only) South Africa support.ze@linksys.com (English only) support.ae@linksys.com (English only) U.S. and Canada support@linksys.com...
  • Page 28: Appendix D: Connector And Cable Specifications

    Appendix RPS1000—Business Series 380W RPS Unit Installation & Administration Connector and Cable Specifications This appendix describes the cable connector that is used to connect the RPS1000 to a supported device. The cable (CAB-RPS-1614=) is a 48-inch (1.2-meter) cable with a 16-pin connector on one end and a 14-pin connector on the other end.
  • Page 29 Appendix RPS1000—Business Series 380W RPS Unit Installation & Administration Pin Number 14-Pin Designation 16-Pin Designation 12 V 12 V 12 V 12 V 12 V 12 V GND–12 GND–12 –48 V GND–48 V RPS_PRES (RPS1000 present) –48 V RPS_CTRL 0 RPS_PRES (RPS1000 present) RPS_CTRL 1 RPS_CTRL 0...
  • Page 30 ©2007 Cisco Systems, Inc. All rights reserved. Linksys is a registered trademark and the Linksys One logo is a trademark of Cisco Systems, Inc.

This manual is also suitable for:

Sge2000 - cisco - gigabit switchRps1000