TABLE 25
This field...
Management modules
<type> Management Module
(<location>)
Code Flash
IronWare Image (Primary or
Secondary)
LP Kernel Image (Monitor for LP
Image Type 0)
LP IronWare Image (Primary or
Secondary for Module Type 0)
BigIron RX Installation Guide
53-1001811-01
Displaying flash memory and version information
Code flash and boot flash information
Displays...
The management module for which flash information is displayed.
The <type> parameter indicates an active or standby management module.
The <location> parameter indicates the top or bottom slot (M1 or M2,
respectively).
The model number and size of the management module's code flash.
Indicates the IronWare image installed in the primary or secondary location
in the management module's code flash. The image name format is
described in
actual image name depends on the version of software you have running
on your BigIron RX Series switch.
The output displays the following information about the image:
Version – "2.3.0Txxy" indicates the image version number. The "Txxy"
is used by Brocade for record keeping. The "xx" indicates the hardware
type, while the "y" indicates the image type.
Size – The size, in bytes, of the image.
Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.
Compilation date and time – The date and time that Brocade compiled
the image.
Indicates the interface modules Boot-Monitor image stored in the
management module's code flash. The management module stores these
images only; it does not run the images. The image name format is
described in
output displays the following information about the image:
Version – "2.3.0Txxy" indicates the image version number. The "Txxy"
is used by Brocade for record keeping. The "xx" indicates the hardware
type, while the "y" indicates the image type.
Size – The size, in bytes, of the image.
Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.
Compilation date and time – The date and time that Brocade compiled
the image.
Indicates the interface modules' primary or secondary IronWare image
stored in the management module's code flash if you copied the primary or
secondary IronWare image to all interface modules using the copy
command with the all keyword. The management module stores these
images only; it does not run the images. The image name format is
described in
output displays the following information about the image:
Version – "2.3.0Txxy" indicates the image version number. The "Txxy"
is used by Brocade for record keeping. The "xx" indicates the hardware
type, while the "y" indicates the image type.
Size – The size, in bytes, of the image.
Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.
Compilation date and time – The date and time that Brocade compiled
the image.
"Software image naming conventions"
"Software image naming conventions"
"Software image naming conventions"
7
on page 165. The
on page 165. The
on page 165. The
169

Advertisement

Table of Contents
loading

Table of Contents