Wiring Diagram - Desa VF-30N-PJD Owner's Operation And Installation Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

IDENTIFYING ERROR SIGNALS FROM RECIEVER
OBSERVED PROBLEM
Long signals (0.8 second tone, 0.2
second break) during ignition
5 second continuous tone
5 short signals (8.2 second tone,
0.2 second break)
111826-04C
TROUBLESHOOTING
POSSIBLE CAUSE
Battery nearly down. (When
signal appears the first time ap-
proximately 10 ignitions left)
Cable is not connected, ON/OFF
switch is in OFF position
Ignition not successful, possible
air in supplyline

WIRING DIAGRAM

MAN Knob
Combination Control
Thermocurrent
Interrupter Block
Ignition Cable
Thermocouple
SPARK
SPARK
Battery Compartment
www.desatech.com
Continued
ON/OFF Switch (Optional)
8 Wire Connecting Cable
Thermocurrent Cable #2
or ON/OFF Switch
Soldered Cable
Thermocurrent Cable #1
Antenna
Receiver
SW
TC
ON/OFF
Switch
Thermocurrent
Interrupter Block
Pilot
4 AA Batteries
REMEDY
Replace battery
Connect cables
Swit to ON. Repeat procedure
Motor Knob
OFF
ON
SW
TC
MA
GR
MO
SW
23