PuraGuard
System
®
Filter Installation System
with Air Dryer
FIGURE 3
PuraGuard
System Filter
®
Installation System without
Air Dryer
FIGURE 4
The PuraGuard
system filter has two female pipe thread
®
air connections: one supply, one delivery — identified by
their relationship to the arrow symbol showing air flow on
the PuraGuard
system filter top cover (see Figure 1).
®
Note: The PuraGuard
®
to be used in conjunction with an alcohol evaporator or
injector. The PuraGuard
or aerosol alcohol introduced, defeat the purpose of the
evaporator/injector and require the sump to be drained more
often than normal.
FILTER BYPASS
(refer to Figure 5)
If a situation occurs where the ability of the filter to allow air
to pass is impaired and causes a pressure difference of
approx. 20 p.s.i. between the air entering the filter element
and exiting, the filter will move downwards against the spring.
The air entering will then be able to bypass the filter element.
PREVENTIVE MAINTENANCE
Important: Review the warranty policy before performing
any intrusive maintenance procedures. An extended warranty
may be voided if intrusive maintenance is performed during
this period.
Because no two vehicles operate under identical conditions,
maintenance intervals will vary. Experience is a valuable
guide in determining the best maintenance interval for a
vehicle.
Every 300 operating hours, or 8,000 miles or one (1)
month:
1. With the air system pressure at 0 p.s.i., use the drain
valve to collect contaminants for disposal.
2
Air
Compressor
Air Dryer
Air
Compressor
system filter is not recommended
system filter will remove the liquid
®
Governor
PuraGuard
®
System Filter
Supply
Reservoir
Governor
PuraGuard
System Filter
Supply
Reservoir
2. Visually check for physical damage to the PuraGuard
system filter such as chaffed or broken air hoses and
broken or missing parts.
3. Check mounting bolts for tightness. Re-torque to vehicle
manufacturers guidelines.
4. Perform the Operation & Leakage Tests listed in this
publication.
FIGURE 5 - PURAGUARD
Primary
Reservoir
Secondary
Reservoir
Primary
Reservoir
®
Secondary
Reservoir
SYSTEM FILTER BYPASS
®
®
FILTER
MOVES
DOWNWARDS
AGAINST
SPRING
FORCE

Advertisement