Cleaning; Troubleshooting; Wiring Diagram - Desa PD15EA Owner's Manual

Outdoor patio table umbrella stand and electric foot warmer
Hide thumbs Also See for PD15EA:
Table of Contents

Advertisement

Available languages

Available languages

CLEANING

DURING SEASON CARE
Always unplug the product before moving or
cleaning.
1. Do not disassemble. Carefully wipe the exte-
rior of unit with a soft, damp cloth.
2. After cleaning, be sure to completely dry the
unit with a cloth or towel.
AFTER SEASON CARE
Store product indoors in a dry location. No main-
tenance is required for this product.

TROUBLESHOOTING

CAUTION: Risk of electric
shock. Do not open. No user servi-
cable parts inside. Take heater to
an authorized service center.
If your product fails to operate:
1. Make sure the electrical outlet GFCI or circuit
breaker and extension cord is working.
2. Check for operation of tip switch. The ON/
OFF switch light can be on but the tip switch
OFF. Move product until a "click" is heard.
To prevent damage of tip switch post, do not
slide product.
3. Look for obstructions around fan. If you find
an obstruction, turn the product OFF and
UNPLUG THE PRODUCT. Have the product
serviced by a qualified individual.
4. Check for tripped thermal protector. Motor
and heating element do not operate. Wait 10
minutes for product to cool. Push reset button.
See Thermal Limit Switch below.
THERMAL LIMIT SWITCH
If product is used in temperatures below 75° F
(28.9° C), the limit switch should not require
resetting unless there is a malfunction. If a mal-
function does occur, have the product serviced by
an authorized service center.
Resetting Thermal Limit Switch
1. Unplug product.
2. Allow product to cool.
3. Turn product upside down.
4. Remove plug on bottom.
5. Insert provided plastic push rod through hole
and guide to small red button on thermal
limit switch (see Figure 4). A flashlight will
improve visability.
113612-01B
6. Lightly push red button to reset switch.
7. Replace removed plug in hole. Perform a trial
operation.
8. If repeated resetting of the thermal limit switch
is required, have the product serviced by an
authorized service center.
POWER PLUG
120V 60Hz
www.desatech.com

WIRING DIAGRAM

ON/OFF
SWITCH
TIP SWITCH
BLACK
HEATING
ELEMENT
WHITE
MANUAL RESET
THERMAL LIMIT
SWITCH
BLACK
BLACK
MOTOR
GREEN
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pg15eaPl15eaPv15ea

Table of Contents