Desa HDCFTP Owner's Operation And Installation Manual page 14

Vent-free compact fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
Removing Valve Cover Shield
1. Open bottom louver assembly by swinging
the assembly down (see Figure 17).
2. Using short Phillips screwdriver, remove the
screw under the center of the branch support.
Rotate valve cover shield clockwise and slide
out. IMPORTANT: Do not remove shoulder
screw on the left side of valve cover shield.
Slide the valve cover shield off of the shoulder
screw (see Figure 17).
Note: If you do not have a short Phillips
screwdriver, the screen, log set, and branch
support must be removed so a longer screw-
driver may be used. See Connecting Equip-
ment Shutoff Valve to Heater Control, page
17, steps 1 and 2.
Shoulder
Screw
Valve
Remove
Cover
Screw
Shield
2
Bottom Louver Assembly
Snap Bushings
Figure 17 - Removing Valve Cover Shield
14
Branch Support
1
www.desatech.com