Troubleshooting - Desa Comfort Glow CGCF26TNA Owner's Operation And Installation Manual

Desa owner's operation and installation manual vent-free natural gas compact fireplace cgcf26tna
Table of Contents

Advertisement

VENT-FREE NATURAL GAS COMPACT FIREPLACE

TROUBLESHOOTING

Note: For additional help, visit DESA
International's Technical Service web
site at www.desatech.com.
Note: All troubleshooting items are listed in
order of operation.
OBSERVED PROBLEM
When ignitor button is pressed, there is no
spark at ODS/pilot
When ignitor button is pressed, there is
spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when
control knob is released
Burner does not light after ODS/pilot is lit
WARNING: Turn off and un-
plug fireplace and let cool before
servicing. Only a qualified ser-
vice person should service and
repair fireplace.
POSSIBLE CAUSE
1. Ignitor cable pinched or wet
2. Ignitor electrode not connected to igni-
tor cable
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned wrong
1. Gas supply turned off or manual shutoff
valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in
PILOT position
4. Air in gas lines when installed
5. ODS/pilot is clogged
6. Gas regulator setting is not correct
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Safety interlock system has been trig-
gered
4. Manual shutoff valve not fully open
5. Thermocouple connection loose at con-
trol valve
6. Pilot flame not touching thermocouple,
which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
7. Thermocouple damaged
8. Control valve damaged
1. Burner orifice is clogged
2. Burner orifice diameter is too small
3. Inlet gas pressure is too low
www.desatech.com
16
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.
REMEDY
1. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
2. Reconnect ignitor cable
3. Replace ignitor cable
4. Replace piezo ignitor
5. Replace ignitor
6. Replace ignitor
1. Turn on gas supply or open manual
shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT
position
4. Continue holding down control knob.
Repeat igniting operation until air is
removed
5. Clean ODS/pilot (see Cleaning and
Maintenance, page 19) or replace ODS/
pilot assembly
6. Replace gas regulator
1. Press in control knob fully
2. After ODS/pilot lights, keep control
knob pressed in 30 seconds
3. Wait one minute for safety interlock sys-
tem to reset. Repeat ignition operation
4. Fully open manual shut-off valve
5. Hand tighten until snug, then tighten 1/4
turn more
6. A) Contact local natural gas company
B) Clean ODS/pilot (see Cleaning and
Maintenance, page 19) or replace ODS/
pilot assembly
7. Replace thermocouple
8. Replace control valve
1. Clean burner (see Cleaning and Mainte-
nance, page 19) or replace burner orifice
2. Replace burner orifice
3. Contact local natural gas company
104277

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents