Wiring Diagram - Desa VK36EN Series Owner's Operation And Installation Manual

Desa direct-vent fireplace owner's operation and installation manual (v)k36en, (v)k36ep
Table of Contents

Advertisement

FIREPLACE INSTALLATION
Continued
OPTIONAL REMOTE CONTROL
INSTALLATION (Model WRC)
Note: If using optional wireless hand-held remote control, the wall
switch must be in the ON position to be operational. The remote control
then becomes the switching mechanism for fireplace operation.
1. Open lower louver panel.
2. The WRC model receiver does not require a battery. The re-
ceiver can be installed by first plugging the short extension
cord into the fireplace receptacle. Then plug the receiver unit
into the extension cord. Finally plug the ignition module plug
into the receiver unit (see Figure 45).
3. Activate the remote handset battery by removing the insulat-
ing tab on the back of the handset (see Figure 46). The battery
is included pre-installed.
4. Once the battery is activated the unit is ready to use.
5. Close lower louver panel.

WIRING DIAGRAM

INCOMING MAIN
GAS SUPPLY
EV1
EV2
GAS LINE TO
BURNER
For more information, visit www.desatech.com
For more information, visit www.desatech.com
111924-01B
Pilot
Burner
Pilot Gas
Line
24V AC
STEP DOWN
TRANSFORMER
120V AC
FIREPLACE INSTALLATION
Optional Remote Control Installation
Fireplace
Receptacle
Extension Cord
Figure 45 - Installing the WRC Remote Receiver
Battery Cover
12 Volt Battery
Back of
Handset
Figure 46 - Installing Battery into Back of Handset
WALL SWITCH
(NOT SUPPLIED)
(SUPPLIED)
BLACK
WHITE
GREEN
ELECTRICAL RATING:
120v, 60Hz, 0.7A
OPTIONAL
REMOTE
CONTROL
WIRING DIAGRAM
Remote Control
Receiver
Ignition
Module Plug
Pull to Remove
Insulation Tab
INCOMING
120V AC
(FUSE BOX
OR BREAKER)
23