FIREPLACE INSTALLATION
18
Installing Optional Blower Accessories (Cont.)
FIREPLACE INSTALLATION
Continued
3.
Place the blower against the lower rear wall of the firebox outer
wrapper with the exhaust port directed upward and the thermodisc
positioned up near the fireplace bottom. The thermodisc must be
oriented near the fireplace bottom as shown in Figure 28 in order
to sense temperature and properly operate. The blower will be
held in position against the back wall by the magnets incorpo-
rated onto the blower housing (see Figure 28).
4.
Be certain that all wire terminals are securely attached to ter-
minals on blower motor and thermal switch, and that the screw
for the thermodisc bracket and green ground wire is tight.
5.
Mount the speed control box against the mounting plate pro-
vided in the lower fireplace cavity by placing the plastic control
shaft forward through the round hole (see Figure 26, page 17).
6.
While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise un-
til it is tight against mounting plate. Place control knob pro-
vided on shaft (see Figure 26, page 17).
7.
Check to make sure that the power cord is completely clear of the
blower wheel and that there are no other foreign objects in blower
wheel. Also double check all wire leads and make sure wire rout-
ing is not pinched or in a precarious position. Correct accordingly.
8.
Turn on power to duplex outlet if previously turned off per the
warning in column 2, page 16.
9.
Plug in blower power cord to duplex outlet.
10. The blower will only run when the speed control knob is in the
ON position and the thermal switch senses temperature after
the fireplace begins to heat up. The blower speed can be ad-
justed by rotating the control knob. To turn off, turn knob fully
counterclockwise until it clicks off. If the blower is ON and
has been running with the fireplace operating, the blower will
continue to run for a short time after the fireplace has been
turned off. As the thermal switch cools down, the blower shuts
down automatically.
11. Peel off the backing paper and stick the supplied wiring dia-
gram decal on the firebox bottom approximately 12" in front
of the blower (see Figure 27, page 17).
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Power Cord
Thermal
Switch
Bracket
Black
Wire
Phillips
Screw
Thermal Switch
Route BKT
Blower Through
This Area
Side View Firebox Bottom
Figure 28 - Blower Model BKT
Blower Wiring Diagram
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
Variable
Fan Switch
1
Off
110/115
V.A.C.
Black
White
Green
Figure 29 - Blower Wiring Diagram for Thermostat-Controlled
Models
White Wire
Blue Wire
Magnetic
Strips
Air Flow
Direction
Ring Terminal
on Green Wire
Air Flow Direction
Thermodisc
Fan Switch
(N.O.)
Black
2
On
Blue
Blower
Motor
Magnets
Blower
Location
108661

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vt32n seriesVt36n seriesVt32p seriesVt36p seriesT36p seriesT32n series ... Show all

Table of Contents