Desa Comfort Glow LFP33PR Owner's Operation And Installation Manual

Desa owner's operation and installation manual unvented (vent-free) propane/lp gas fireplace lfp33pr remote ready gas fireplace system lfp33pr

Advertisement

UNVENTED (VENT-FREE)
PROPANE/LP GAS FIREPLACE
OWNER'S OPERATION AND INSTALLATION MANUAL
LFP33PR
REMOTE READY
GAS FIREPLACE
SYSTEM
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's in-
structions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where
not prohibited by state or local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
*
Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Shown with optional cabinet
mantel and hearth base.
WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it
is installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to Air for Combustion and
Ventilation section on page 4 of
this manual.

Advertisement

Table of Contents
loading

Summary of Contents for Desa Comfort Glow LFP33PR

  • Page 1 UNVENTED (VENT-FREE) PROPANE/LP GAS FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL LFP33PR REMOTE READY GAS FIREPLACE SYSTEM WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
  • Page 2: Safety Information

    Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. LFP33PR If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building •...
  • Page 3: Product Identification

    PRODUCT IDENTIFICATION Control Knobs Piezo Ignitor Remote Selector Switch (Optional) Figure 1 - Log Base Assembly Top Louvered Hood Firebox Support Screen Assembly Figure 2 - Fireplace 104888 OWNER’S MANUAL Log Set Optional Remote Control Top Outer Casing Rear Access Door Bottom Louver Assembly...
  • Page 4: Product Features

    The GA3650T blower operates thermostatically. The blower circulates heated air from the fireplace into the room. Use of blower is optional. See Accessories, pages 24 and 25. LFP33PR AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space...
  • Page 5 AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 6 IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent. LFP33PR Ventilation Grills Into Adjoining Room,...
  • Page 7: Installation

    INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater.
  • Page 8: Conventional Fireplace Installation

    Corner Mantel built-in installation. Floor - 0" 16" Figure 7 - Minimum Clearance to Wall and Ceiling LFP33PR CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fireplace along with the corner, face, or cabinet mantel with hearth base accessories against a wall in your home.
  • Page 9 INSTALLATION Continued 11. Carefully insert fireplace into cabinet mantel. Be careful not to scratch or damage hearth base, cabinet mantel, or any laminate trim on hearth base. Re- move protective material from top of hearth base and from front of fireplace (if any).
  • Page 10: Installing Gas Piping To Fireplace Location

    Framing Material Firebox Wire-mesh Screen Figure 15 - Minimum Mantel Clearances for Built-In Installation LFP33PR INSTALLING GAS PIPING TO FIREPLACE LOCATION WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the propane/LP supply.
  • Page 11: Connecting Fireplace To Gas Supply

    INSTALLATION Continued Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 16, page 10). Check your building codes for any special requirements for locating manual shutoff valve to fireplaces.
  • Page 12: Checking Gas Connections

    Correct all leaks at once. Reconnect fireplace and manual shutoff valve to gas supply. Check reconnected fittings for leaks. LFP33PR Test Pressures Equal To or Less Than 1/2 PSIG Close manual shutoff valve (see Fig- ure 20).
  • Page 13: Installing Logs

    INSTALLATION Continued INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. CAUTION: Do not remove the warning and instruction labels attached to the heater base as- sembly.
  • Page 14 Wires Figure 27 - Switch Plate and Wiring Harness Screws Terminal Wires Nuts Remote Receiver Figure 28 - Installing Remote Receiver LFP33PR White Wire From Receiver Valve Red Wire From Receiver Figure 29 - Connecting Wires INSTALLING BATTERIES FOR RM4...
  • Page 15 INSTALLATION Continued OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL ACCESSORY GHRC and GHRCT SERIES Installing Remote Receiver Unit 1. Disconnect switch wires from the con- trol valve. 2. Remove screws attaching switchplate. 3. Remove switch plate (see Figure 32). Discard after removing. 4.
  • Page 16: Operating Fireplace

    LFP33PR LIGHTING INSTRUCTIONS WARNING: You must operate this fireplace with the fireplace screen in place.
  • Page 17: Manual Lighting

    OPERATING FIREPLACE Continued WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position. Pilot Burner Ignitor Electrode Figure 38- Pilot...
  • Page 18: Inspecting Burners

    If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot. LFP33PR CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning.
  • Page 19: Troubleshooting

    TROUBLESHOOTING Note: For additional help, visit DESA International’s Technical Service web site at www.desatech.com. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/pilot When ignitor button is pressed, there is...
  • Page 20 White powder residue forming within burner box or on adjacent walls or furniture Remote does not function LFP33PR POSSIBLE CAUSE 1. Burner orifice clogged 2. Inlet gas pressure is too low 3. Burner orifice diameter is too small 4.
  • Page 21 TROUBLESHOOTING Continued • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your • Immediately call your gas supplier from a neighbor’s phone. Follow the •...
  • Page 22: Wiring Diagram

    If so, contact your local propane/LP gas supplier. TECHNICAL SERVICE You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564). You can also visit DESA International’s Technical Service site www.desatech.com.
  • Page 23: Replacement Parts

    This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800- 337-2564). When calling DESA International, have ready •...
  • Page 24 ACCESSORIES Purchase these fireplace accessories from your local dealer or Parts Central. If they can not supply these accessories, call DESA International’s Sales Department at 1-800- 458-2472 for referral information. You can also write to the address listed on the back page of this manual.
  • Page 25 ACCESSORIES Continued MANUAL SHUTOFF VALVE GA5010 For all models. Manual shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe. BLOWER ACCESSORIES Increase air circulation to maximize heat distribution. GA3650T - T/Stat Blower (for t/stat fireplaces only) Features ON/OFF/AUTO setting. In the auto position, the blower will automatically cycle on and off as needed.
  • Page 26: Illustrated Parts Breakdown

    UNVENTED PROPANE/LP GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL LFP33PR LFP33PR 104888...
  • Page 27: Parts List

    PARTS LIST REMOTE READY MODEL LFP33PR 104888 This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. PART NUMBER DESCRIPTION 104937-01 Log #1, Middle 104938-01...
  • Page 28 LFP33PR UNVENTED PROPANE/LP GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN FIREPLACE LFP33PR 104888...
  • Page 29 PARTS LIST FIREPLACE LFP33PR 104888 This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. PART NUMBER DESCRIPTION 101357-01 Top Outer Casing 103207-01 Outer Casing...
  • Page 30: Warranty Information

    COMFORT GLOW VENT-FREE PROPANE/LP GAS FIREPLACE DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.

Table of Contents