Desa Comfort Glow CGCF26NR Owner's Operation And Installation Manual page 15

Desa owner's operation and installation manual vent-free natural gas compact fireplace cgcf26nr
Table of Contents

Advertisement

OPERATING
FIREPLACE
Continued
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
to the OFF position.
2. Set remote selector switch in the OFF
position to prevent draining battery.
Shutting Off Burner Only (pilot
stays lit)
You may shut off the burners and keep
the pilot lit by doing one of the following:
1. Turn control knob clockwise
to the PILOT position.
2. Use remote control manual OFF button.
3. Set remote selector switch in the OFF
position.
THERMOSTAT
CONTROL
OPERATION
The thermostat control setting on the
remote control unit can be set to any
comfort level between HI and LO. The
burners will turn on and off automati-
cally to maintain the comfort level you
select. The ideal comfort setting will vary
by household depending upon the amount
of space to be heated, the output of the
central heating system, etc.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under
Lighting Instructions, page 14.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 9 on page 14.
104326
HAND HELD REMOTE
OPERATION
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions on page 14.
1. After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI
and LO. Slide the remote selector
switch to the REMOTE position. The
burners will come on. You can now
turn the burners on and off with the
hand-held remote control unit.
IMPORTANT: Do not leave the re-
mote selector switch in the REMOTE
position when the pilot is not lit. This
will drain the battery.
2. Select the MANUAL or AUTO but-
ton on the hand-held remote control
unit.
• In MANUAL mode, turn burners
on or off by pressing the ON or
OFF buttons on the hand-held re-
mote control unit.
• In AUTO mode, the room tempera-
ture is controlled by the thermo-
stat in the hand-held remote con-
trol unit. To increase the room tem-
REMOTE
OFF
ON
Remote Selector Switch in Remote Position
Figure 25 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment
Knob for Remote Operation
Shows Temperature
Setting
Allows Burners to be
Turned On and Off
with the Hand-Held
Remote Unit.
The log heater will
automatically cycle
between pilot and the
heat setting that has
been selected.
Figure 26 - Thermostat Hand-Held Remote Control Unit Selections
15
OWNER'S MANUAL
perature, press the top arrow of the
TEMP button. To lower room the
temperature, press the bottom ar-
row to the TEMP button. At higher
settings the heater will run more.
IMPORTANT: The hand-held re-
mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close the
heater. The thermostat on the
hand-held remote control unit will
heat up too quickly and turn the
heater off.
3.
Use the STATUS button on the hand-
held remote control unit to see the
operation mode being used and the
temperature setting selected. A red
light will come on beside the opera-
tion mode being used when the sta-
tus button is pressed.
4.
To turn the burners off when oper-
ating in the MANUAL mode, press
the OFF button. If operating in the
auto mode, press the manual button,
then press the OFF button The pilot
will remain lit.
IMPORTANT: To turn the pilot off,
manually turn the control knob on the
heater to the OFF position or set re-
mote selector switch to OFF position.
Control Knob in
On Position
Increases Room
HI
Temperature
TEMP
Decreases Room
Temperature
Turns Burners
LO
MAN
ON
On and Off
AUTO
OFF
Shows Current
Operation Mode
STATUS
Flame Adjustment Knob

Advertisement

Table of Contents
loading

Table of Contents