Desa Comfort Glow CF26PRA Owner's Operation And Installation Manual page 27

Desa owner's operation and installation manual unvented (vent-free) bay front gas log fireplace cf26pra , cf26nra
Table of Contents

Advertisement

OBSERVED PROBLEM
Moisture/condensation noticed
on windows
Heater produces a whistling
noise when burners are lit
White powder residue forming
within burner box or on adjacent
walls or furniture
Remote does not function
Heater produces a clicking/tick-
ing noise just after burners are
lit or shut off
113897-01A
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Not enough combustion/ven-
tilation air
1. Turning control knob to HI po-
sition when burners are cold
2. Air in gas line
3. Air passageways on heater
blocked
4. Dirty or partially clogged
burner orifice(s)
1. When heated, vapors from
furniture polish, wax, carpet
cleaners, etc. may turn into
white powder residue
1. Battery is not installed. Bat-
tery power is low
1. Metal expanding while heating
or contracting while cooling
www.desatech.com
REMEDY
1. Refer to Air for Combustion
and Ventilation requirements
(page 5)
1. Turn control knob to LO position
and let warm up for a minute
2. Operate burners until air is
removed from line. Have gas
line checked by local natural
or propane/LP gas company
3. Observe minimum installation
clearances (see page 9)
4. Clean burners (see Cleaning
and Maintenance, page 23)
or replace burner orifice
1. Turn heater off when using
furniture polish, wax, carpet
cleaners, or similar products
1. Replace 9-volt batteries in
receiver and hand held-remote
control
1. This is common with most
heaters. If noise is excessive,
contact qualified service
person
27