IMPORTANT SAFETY INSTRUCTIONS This lightning flash with arrowhead symbol, within The exclamation point within an equilatereal triangle is an equilateral triangle, is intended to alert the user to intended to alert the user to the presence of important the presence of uninsulated “dangerous voltage” operating and maintenance (servicing) instructions in within the product’s enclosure that may be of sufficient the literature accompanying the appliance.
Page 4
MODEL TYPE: YS1003 Block Diagram for YCV50B SPLITTER PREAMP D E S I G N E D A N D M A N U F A C T U R E D B Y Y O R K V I L L E S O U N D 12AX7 12AX7 12AX7...
Page 8
These parts are X581 stuffed ONLY on 1/4W X581_ 220K MINI M581 (YCV40) These parts are X613 400V stuffed ONLY on X613_ M613 (YCV50BLUE) 1/4W 1/4W 1/4W 470K 270K 3682 SPLITTER OUTPUT 1324M OUTPUT V3:A V4:A 1.0W 3682 OUTPUT 100N 2X_TRIODE_HCT 1/4W 220R...
Page 10
X8004 Version History M581 PCB HISTORY MODEL(S):- MODEL(S):- YCV40/YCV50BLUE YCV40 DATE VER# DESCRIPTION OF CHANGE DATE VER# DESCRIPTION OF CHANGE 23-APR-2008 14.00 Released for Production NOV/02/00 1.00 FIRST PRODUCTION PC7625,M581 R78 27K>18K#4831.M613 R78 18K>15K#4830 NOV/08/00 PC#6305 R63 2K2->3K3 R40 24K->27K PC7649, CHANGE P12 22K #4517 TO 10K #4520 DEC/14/00 2.00...
Page 12
SEE LAYOUT DIAGRAM YCV50BLUE M613 v14.00 X8004 Version History X8004 DRILL HISTORY MODEL(S):- MODEL(S):- YCV40/YCV50BLUE YCV40/YCV50BLUE DATE VER# DESCRIPTION OF CHANGE DATE VER# DESCRIPTION OF CHANGE 23-APR-2008 14.00 Released for Production PC7625,M581 R78 27K>18K#4831.M613 R78 18K>15K#4830 PC7649, CHANGE P12 22K #4517 TO 10K #4520 X8004 PENDING CHANGES MODEL(S):- YCV40/YCV50BLUE...
Page 13
SEE LAYOUT DOCUMENTATION PRODUCTION NOTES 6. BEND C69 OVER Q7 AS FAR AS POSSIBLE BEFORE 1. RTV MUST BE ADDED TO THE FOLLOWING CAPS ADDING RTV C1,C16,C19,C17,C70 BETWEEN C84,C28,C60,C15 BETWEEN C49,C50, ADDED TO C15,C7,C8,C3,C9 7. PCBSA: BREAK OUT BOARD BEFORE TESTING C56,C14,C6,C10,C4,C2 AND C12 2.
Page 15
YCV50BLUE m613 Service Update for V2.10 boards April 2005 boards have been reworked as described in this document. To address PC#6865 a 22AWG wire, part # 3947 jumper, needs to be soldered from P10 to S3 on the bottom side of the board as shown: SERVIC BULLET YCV50-...
Page 17
YCV50BLUE m613 Service Update for V2.10 boards (additional) 1. First complete the Service fix PC#6865 as described in the pdf: Service_YCV50-m613_Update_for_V2.10_PC#6865.pdf To upgrade the unit from v2.10 to v2.20 PC#6889, complete the following: 2. Replace jumper X61 with a 1K resistor, #4823:...
Page 18
R E D ME T A L _ B A C K T O E Y E 9 W C 1 1 GR AY G R A Y R E D WC 8 + 2 4 V B R O W N B R O W N S UPPLY E Y 9...