Desa (V)T32P Owner's Operation And Installation Manual page 9

Direct-vent fireplace ng/lp “tudor” models
Table of Contents

Advertisement

VENTING INSTALLATION
INSTRUCTIONS
Continued
7. Slide the wall firestop over the vent pipe before connecting
horizontal run to vent cap (see Figure 12).
8. Carefully move fireplace, with vent assembly attached, toward
wall and insert vent pipe into horizontal termination. The pipe
overlap should be a minimum of 1
9. Slide wall firestop against interior wall surface and attach with
screws provided. See Figure 13 for horizontal termination
details.
10. Place fireplace into position and shim with noncombustible
material if needed. Nail or screw side flanges to framing to
secure unit in place. IMPORTANT: Make sure fireplace is
level before securing. If fireplace is not level it will not work
properly.
Apply Mastic to
All Four Sides
Figure 11 - Installing Siding Standoff
Vent Cap
(Horizontal
Termination)
Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe
108661-01F
/
".
1
4
Cut Siding Away
to Fit Standoff
Standoff
Wood Screw
Vent Cap
Interior Wall
Surface
Wall
Firestop
Screw
Direct Vent
Pipe
Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall
Figure 13 - Typical Horizontal Termination Cap Mounting with
Screws
Horizontal
Vent Pipe
www.desatech.com
Minimum Pipe
Overlap 1
/
"
1
4
Wall
Firestop
10" x 10"
Framed
Opening
Additional Siding Standoff Installed
Siding Standoff
Screws
High Wind
Termination
Apply Mastic to
Outside Edge of
Standoff
Exterior Wall
with Vinyl Siding
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents