Desa (V)T32EN SERIES Owner's Operation And Installation Manual page 11

Direct-vent fireplace ng/lp “tudor” models
Table of Contents

Advertisement

VENTING INSTALLATION
INSTRUCTIONS
Continued
Minimum Pipe
Overlap 1
/
"
1
4
Direct-Vent
Pipe
Wall
Firestop
Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall
10" x 10" Framed
Opening
Exterior Wall with Vinyl Siding
Figure 13 - Typical Horizontal
Termination Cap Mounting with
Additional Siding Standoff Installed
Horizontal Termination Configurations
Figures 14 through 18 show different configura-
tions and alternatives for venting with horizontal
termination. Each figure includes a chart with
critical minimum and maximum dimensions which
MUST be met. IMPORTANT: If using a venting
configuration of only horizontal venting with no
vertical run, a 1/4" rise for every 12" of run toward
the termination is required.
NOTICE: Do not seal termination
cap to vent pipe. Cap must be
removable for vent inspection
and maintenance.
WARNING: Never run vent
downward as this may cause
excessive temperatures which
could cause a fire. Operation of
improperly installed and main-
tained venting system could
result in serious injury, property
damage or loss of life.
111987-01D
Siding Standoff
Screws
High Wind
Termination
Apply
Mastic to
Outside
Edge of
Standoff
www.desatech.com
GROUND FLOOR INSTALLATION
Recommended Applications:
• Installation using cabinet surrounds
• Through the wall using round or square termina-
tion (up to 12" horizontal pipe)
• NOT FOR CORNER INSTALLATION
Adjustable
Horizontal
Pipe 1" Max.
High Wind
Square
Termination
Wall Firestop
Vertical (V)
9" min.
45° Elbow
Wall
Firestop
* If installing this fireplace at altitudes of
4000 feet and above, it is recommended
that an additional vertical height of 6" be
added to the vent system.
Figure 14 - Horizontal Termination
Configuration for Square and Round
Terminations
45° Elbow
Square Termination
Horizontal (H)
17" Max.
Exterior Portion
of Wall Firestop
(Round
Termination
Only)
Slide Ring
Over Elbow
to Complete
Connection
Round
Termination
Cap
Round Termination
(Kit HTK Shown)
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vt32ep seriesT32en seriesT32ep series