Decorative Facing; Burner Flame Adjustment - Desa Vanguard EVDDVF36PN Owner's Operation And Installation Manual

Desa owner's operation and installation manual direct-vent gas fireplace evddvf36pn, evddvf36stn
Table of Contents

Advertisement

INSTALLATION
Continued
WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Refer
to this manual. For assistance or
additional information, consult a
qualified installer, service
agency, or gas supplier.
B
D
A
E
C
B
Figure 43 - Log Set (9 Pieces)
Left
Right
Figure 44 - Burner and Grate (Top View)
Left
Right
Figure 45 - Installing Logs "A" (Top View)
Left
A
B
A
Right
Figure 46 - Installing Logs "B " (Top View)
106573
Figure 47 - Installing Twigs "C, D, E " (Top
View)
C

DECORATIVE FACING

Any noncombustible material may be used
for facing (glass, tile, brick, etc.) as long as
A
the proper clearances are observed (see
Clearances, page 4). IMPORTANT: Lou-
vered openings must not be obstructed, and
upper and lower panels must remain remov-
D
able for servicing. Use only heat-resistant,
noncombustible mortar or adhesive when
securing facing material.
Note: Combustible material, such as wood,
that has been fireproofed is not considered
noncombustible.
ELECTRODE
ASSEMBLY
ADJUSTMENT
The electrode assembly is factory preset for
proper operation. Alteration to these settings
may have occurred during shipping and han-
dling. If this is the case, some minor adjust-
ments may be necessary and should be done
by a qualified technician. To access the elec-
trode, the glass door must be opened. The
proper settings for the electrode height should
be at a distance of 5/8" from the top of the
burner as shown in Figure 48.
Top of Burner
B
Figure 48 - Burner and Electrode (Side
View)
OWNER'S MANUAL
Left
D
C
E
C
D
Right
1/8"
(3mm)
Port Hole
19
Figure 49 - Burner and Electrode (Top
View)
BURNER FLAME
ADJUSTMENT
The air shutter, located at the underside of the
main burner (see Figure 50), has been factory
preset to the proper air-to-gas ratio which
results in an even, clean burning flame across
the burner (see Figure 51). If readjustment is
necessary, you can restore the proper air-to-
gas ratio by loosening the air shutter screw
and rotating the air shutter until the proper
flame setting is achieved (the shutter's nor-
mal setting is "full opened". Do not forget to
retighten the air shutter screws.
Orifice
Air Shutter
Firebox Bottom
Figure 50 - Connecting Venturi and Orifice
CORRECT
INCORRECT
CLOSE
SHUTTER
5/8"
(15.8mm)
INCORRECT
OPEN
SHUTTER
Figure 51 - Burner Flame Patterns
0.75
0.34
Burner
Venturi
Tube
Burner Gas Line
Long, Blue Flame
with Yellow Tips
Short, Sharp,
Blowing Flame
Long, Uneven,
Yellow Flame
Continued

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vanguard evddvf36stn

Table of Contents