Operating Heater - Desa VP10A. VN10TA Owner's Operation And Installation Manual

Vent-free gas heater
Table of Contents

Advertisement

INSTALLATION
Continued
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 14,
page 12).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knob of heater is in the OFF
position.
4. Check all joints from equipment shutoff valve
to control valve (see Figures 15 or 16, page
12). Apply a noncorrosive leak detection fluid
to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 13).
Check the rest of the internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appli-
ance, pages 14, 16 or 17, depending on your
model).
8. Replace front panel.

OPERATING HEATER

MANUAL CONTROL
BLUE FLAME MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighborʼs phone. Follow the gas
supplierʼs instructions.
• If you cannot reach your gas supplier, call
the fire department.
110720-01G
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, donʼt
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified
service technician to inspect the appliance and
to replace any part of the control system and
any gas control which has been under water.
1. STOP! Read the safety information starting
in column 1.
2. Make sure equipment shutoff valve is fully
open.
3. Turn control knob clockwise
OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information, column 1. If you donʼt
smell gas, go to the next step.
5. Press in control knob and turn counter-
clockwise
Keep control knob pressed in for five (5)
seconds (see Figure 17).
Note: You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
• If control knob does not pop up when
released, contact a qualified service person
or gas supplier for repairs.
Ignitor Button
Figure 17 - Control Knob In The OFF
www.desatech.com
LIGHTING
INSTRUCTIONS
to the PILOT position.
Control Knob
PILOT
HIGH
IGNITOR
LOW
Position
Thermocouple
Ignitor Electrode
Pilot Burner
Figure 18 - Pilot
to the
OFF
13

Advertisement

Table of Contents
loading