Technical Service; Specifications; Service Hints - Desa NATURAL GAS LOG HEATER Owner's Operation And Installation Manual

Unvented (vent-free) natural gas log heater
Table of Contents

Advertisement

TECHNICAL
SERVICE

SPECIFICATIONS

SERVICE
HINTS
101308
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International's Technical Service Department at
1-800-DESA LOG (1-800-337-2564).
18" Thermostat- 24" Thermostat- 30" Thermostat-
Controlled
Btu (Variable)
16,000/26,000
Type Gas
Natural Gas Only
Ignition
Piezo
Manifold Pressure
3.4" W.C.
Inlet Gas
Pressure (in. of water)
Maximum
10.5"
Minimum*
5"
* For purpose of input adjustment
Shipping Weight
36 lbs.
18" Manually-
Controlled
Btu (Variable)
8,000/14,000/
26,000
Type Gas
Natural Gas Only
Ignition
Piezo
Manifold Pressure
3.4" W.C.
Inlet Gas
Pressure (in. of water)
Maximum
10.5"
Minimum*
5"
* For purpose of input adjustment
Shipping Weight
36 lbs.
When gas pressure is too low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
When gas quality is bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.
Controlled
Controlled
20,000/33,000
21,500/36,000
Natural Gas Only
Natural Gas Only
Piezo
Piezo
3.4" W.C.
3.4" W.C.
10.5"
10.5"
5"
5"
38 lbs.
40 lbs.
24" Manually-
30" Manually-
Controlled
Controlled
10,000/17,000/
11,000/18,000/
33,000
36,000
Natural Gas Only
Natural Gas Only
Piezo
Piezo
3.4" W.C.
3.4" W.C.
10.5"
10.5"
5"
5"
38 lbs.
40 lbs.
31