OPERATING
HEATER
Continued
101867
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow "B" in the safety information
at the top of page 16. If you don't smell gas, go to the next step.
5. Press in control knob, and turn counterclockwise
Keep control knob pressed for five seconds.
You may be running this heater for the first time after hooking up
Note:
to gas supply. If so, the control knob may need to be pressed in for 30
seconds. This will allow air to bleed from the gas system.
• If control knob does not pop up when released, contact a qualified
service person or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor button. This
will light pilot. The pilot is attached to the front of burner. If needed, keep
pressing ignitor button until pilot lights.
Note:
If pilot does not light, refer to Troubleshooting, pages 21 through
24. Also contact a qualified service person or gas supplier for repairs.
Until repairs are made, light pilot with match, see Manual Lighting
Procedure, page 19.
Thermocouple
7. Keep control knob pressed in for 10 seconds after lighting pilot. After 10
seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
C-clockwise
Ignitor Electrode
Pilot Burner
Figure 16 - Pilot
to pilot position.
Continued