Inspecting Pilot And Burner Flame; Pilot Flame Pattern; Burner Flame Pattern - Desa Comfort Glow CGB35N Owner's Operation And Installation Manual

Desa vented natural gas heaters owner's operation and installation manual cgb35n, cgb50n
Table of Contents

Advertisement

INSPECTING
PILOT AND
BURNER
FLAME
100351
Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
prevent the thermocouple from getting hot, causing the heater to shut down.
Figure 18 - Correct Pilot
Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 19
• turn heater off (see To Turn Off Gas to Appliance, page 22)
• contact a qualified service person

BURNER FLAME PATTERN

Note:
To view burner flame, look through front glass of heater.
Figure 20, page 24 shows a correct burner flame pattern. Figure 21, page 24 shows
two incorrect burner flame patterns. The two incorrect flame patterns show high
yellow flames and flames lifting off of burner.
If high yellow flame occurs, your heater could produce
increased levels of carbon monoxide. If burner flame is
incorrect, follow instructions on page 24.
Do not mistake orange flames with yellow flame. Dirt or
other fine dust particles enter the heater and burn
causing brief patches of orange flame.
Thermocouple
Figure 19 - Incorrect
Pilot Flame Pattern
WARNING
WARNING ICON
G 001
NOTICE
Thermocouple
Continued
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comfort glow cgb50n

Table of Contents