Troubleshooting - Master B350CE Owner's Manual

High pressure portable forced air heater
Table of Contents

Advertisement

TROUBLE-
SHOOTING
101964
Never service heater while it is plugged in, operating, or hot.
Severe burns and electrical shock can occur. Only a qualified
service person should service and repair heater.
OBSERVED
POSSIBLE CAUSE
PROBLEM
Motor does not
1. No power or low voltage
start when heater
at heater due to:
is plugged in and
A) Damaged power cord
thermostat setting
or extension cord
is higher than
B) Wrong size extension
surrounding air
cord
temperature.
C) Heater plugged into
outlet with voltage lower
than 220/240 volts
2. Loose electrical connec-
tions
3. Motor overload protector
tripped due to:
A) Dirty fan
B) Debris pulled into fan
area by fan
C) Binding pump
D) Low voltage
4. Flame-out control not reset
5. Damaged flame-out
control
6. Damaged power relay
7. Damaged thermostat
8. Binding pump
WARNING
REMEDY
1. A) Check condition of
power cord or extension
cord. Repair or replace if
damaged.
B) Use extension cord with
proper wire size (see To
Start Heater, page 8).
C) Make sure heater is
plugged into 220/240 volt,
50 hertz outlet.
2. Check connections.
Tighten if loose.
3. A) See Fan Blades, page 14.
B) Remove debris from fan
and fan guard area.
C) Turn fan by hand. If fan
is hard to turn, see Pump,
page 16.
D) See steps B and C under
item 1 above.
Note:
motor overload protector
by pressing reset button on
top of motor.
4. Press and release flame-out
control reset button. See
Figure 4, page 8 for button
location.
5. Replace flame-out control.
6. Replace power relay.
7. Replace thermostat.
8. Turn fan by hand. If fan is
hard to turn, see Pump, page
16.
Be sure to reset
11

Advertisement

Table of Contents
loading