CHECKING
GAS
CONNECTIONS
Continued
16
3. Pressurize supply piping system by either using compressed air or
opening propane supply tank valve.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and
water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (see Figure 15).
2. Pressurize supply piping system by either using compressed air or opening
propane supply tank valve.
3. Check all joints from propane supply tank to manual shutoff valve (see Figure
16). Apply mixture of liquid soap and water to gas joints. Bubbles forming
show a leak.
4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open manual shutoff valve (see Figure 15).
2. Open propane supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve (see Figure
16). Apply mixture of liquid soap and water to gas joints. Bubbles forming
show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 17 through 19). Check all other
internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 19).
8. Replace front panel.
Manual
Shutoff
Valve
Figure 15 - Manual Shutoff Valve
Propane
Supply Tank
Figure 16 - Checking Gas Joints
ON
Open
POSITION
OFF
POSITION
Closed
Thermostat Gas Valve
Manual
Shutoff
Valve
101811

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vp2800btbCfp2800btbVp2000btbCfp2000btb

Table of Contents