DENON AVR/AVC control protocol
Application model : AVR-3805/AVC-3890
Application terminal : RS-232C
Connector specification
Connector type : DB-9pin female type, slave straight connection (DCE type)
( 1pin : GND , 2pin : TxD , 3pin : RxD , 5pin : Common(GND) , 4,6,7,8,9pin : NC )
Communication format :
Synchronous system
communication system
Communication speed
Character length
Parity control
Start bit
Stop bit
Communication procedure
Communication data length
: Tone step synchronization
: A half duplex
: 9600bps
: 8 bits
: None
: 1 bit
: 1 bit
: Non procedural
: 135 bytes (maximum)
- 1 -
Ver. 4.0

Advertisement

loading

Summary of Contents for Denon AVR-3805

  • Page 1 DENON AVR/AVC control protocol Application model : AVR-3805/AVC-3890 Application terminal : RS-232C Connector specification Connector type : DB-9pin female type, slave straight connection (DCE type) ( 1pin : GND , 2pin : TxD , 3pin : RxD , 5pin : Common(GND) , 4,6,7,8,9pin : NC )
  • Page 2: Protocol Specification

    Protocol specification The following three data forms is defined. COMMAND The message sent to a system(AVR/AVC) from a controller(Touch Panel etc.) A command to a system is given from a controller. EVENT The message sent to a controller(Touch Panel etc.) from a system(AVR/AVC) The result is sent, when a system is operated directly and a state changes.
  • Page 3 The example of a command * <CR> is the meaning of 0x0D. SIDVD<CR> : Select Input source DVD MSTHX SURROUND EX<CR> : surround Mode Set to THX SURROUND EX MVUP<CR> : Master Volume UP PWON<CR> : system PoWer ON PWSTANDBY<CR> : system PoWer STANDBY SI?<CR>...
  • Page 4 Others A) COMMAND is receivable also during transmission of EVENT. B) Since CHANNEL VOLUME changes simultaneously when the SURROUND MODE changes, the value of the channel volume of all channels returns as EVENT. C) CHANNEL VOLUME returns the data of ALL channels by the present SURROUND MODE also including an intact channel. In this case, the data of an intact channel is set to "50".
  • Page 5 COMMAND and PARAMETER list COMMAND PARAMETER STANDBY DOWN FL UP FL DOWN FL ** FR UP FR DOWN FR ** C UP C DOWN C ** SW UP SW DOWN SW ** SL UP SL DOWN SL ** SR UP SR DOWN SR ** SBL UP...
  • Page 6 ---Select CDR/TAPE function at AVR-3805 ---Invalid at AVR-3805 MAIN-ZONE ON/OFF change at AVR-3805 MULTI ZONE-3 mode set , and select source at AVR-3805 Z1PHONO<CR> ---The name of PARAMETER is the same as that of the time of SI COMMAND. MULTI ZONE-3...
  • Page 7 AUTO ANALOG EXT.IN-1 EXT.IN-2 function MULTI ZONE-2 mode set , and select source at AVR-3805 Z2PHONO<CR> ---The name of PARAMETER is the same as that of the time of SI COMMAND. MULTI ZONE-2 mode cancel MULTI ZONE-2 VOLUME UP/DOWN , direct change to ***dB Z2UP<CR>...
  • Page 8 SURROUND mode set All are received as "DOLBY SURROUND" , the surround mode which changed return as EVENT. All are received as "DTS SURROUND" , ---Invalid at AVR-3805 ---Invalid at AVR-3805 ---Invalid at AVR-3805 ---Invalid at AVR-3805 ---Invalid at AVR-3805...
  • Page 9 EVENT PARAMETER MPEG2 AAC AAC+DOLBY EX TONE DEFEAT ON PARAMETER setting TONE DEFEAT OFF TONE DEFEAT ON/OFF SB:MTRX ON SURROUND BACK SP MODE set SB:NON MTRX ---MTRX ON = SURR.EX ON = DSCRT ON SB:PL2xCINEMA SB:PL2xMUSIC SB:OFF CINEMA EQ.ON CINEMA EQ.OFF MODE : MUSIC MODE : CINEMA MODE : GAME...
  • Page 10 00 = OFF (define ONLY SWch in DIRECT mode.) (at SBch 2SP) (at SBch 2SP) (at SBch 1SP) OUTPUT MUTE ON/OFF change INPUT source change ---Select DBS function at AVR-3805 ---Invalid at AVR-3805 ---Select CDR/TAPE function at AVR-3805 ---Invalid at AVR-3805 - 10 - example *RES.
  • Page 11 EVENT PARAMETER PHONO CDR/TAPE1 SOURCE PHONO CD/TAPE1 SOURCE PHONO CD/TAPE1 SOURCE function MAIN-ZONE ON/OFF change MULTI ZONE-3 source change ---The name of PARAMETER is the same as that of the time of SI COMMAND. MULTI ZONE-3 mode cancel MULTI ZONE-3 VOLUME change , **:00 to 99 by ASCII 98 = +18dB(MAX) 80 = 0dB...
  • Page 12 EVENT PARAMETER ****** (6 digits) TUNER Frequency change **(PRESET No.) AUTO MANUAL *RES. : NOT returns '? ' parameters as RESPONSE. function --- ****.** kHz at AM band ****.** MHz at FM band TUNER PRESET change to No.** TUNER BAND , MODE change ---Band set to AM ---Band set to FM ---Tuning mode set to AUTO mode...
  • Page 13 EVENT PARAMETER DIRECT PURE DIRECT STEREO MULTI CH IN MULTI CH IN +PL2x CINEMA MULTI CH IN +PL2x MUSIC MULTI CH DIRECT MULTI CH DIRECT +PL2x CINEMA MULTI CH DIRECT +PL2x MUSIC MULTI CH PURE D MULTI CH PURE D +PL2x CINEMA MULTI CH PURE D +PL2x MUSIC...
  • Page 14 DTS NEO:6 CINEMA DTS NEO:6 MUSIC DTS SURROUND DTS ES DSCRT6.1 DTS ES MTRX6.1 DTS+PL2x CINEMA DTS+PL2x MUSIC DOLBY H/P ---Invalid at AVR-3805 DTS+DOLBY H/P ---Invalid at AVR-3805 HOME THX CINEMA ---Invalid at AVR-3805 THX5.1 ---Invalid at AVR-3805 THX U2 CINEMA...
  • Page 15 EVENT PARAMETER ROOM EQ:NORMAL ROOM EQ:FRONT ROOM EQ:FLAT ROOM EQ:MANUAL ROOM EQ:OFF *RES. : NOT returns '? ' parameters as RESPONSE. function ROOM EQ mode change - 15 - example *RES. PSROOM EQ:NORMAL<CR> PSROOM EQ:FRONT<CR> PSROOM EQ:FLAT<CR> PSROOM EQ:MANUAL<CR> PSROOM EQ:OFF<CR>...