04. VOLUME Gain Data
Function
The external control equipment changes the VOLUME gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER SOUND Gain Flag 05H
DATA01: VOLUME Gain Flag
DATA02: VOLUME Gain
ACK
7FH 60H 80H 7FH 02H DATA00
DATA00: USER SOUND Gain Flag
DATA01: VOLUME Gain Flag
05. AUDIO Mute ON
Function
The external control equipment switches on AUDIO Mute of the plasma
monitor.
Transmission Data
9FH 80H 60H 3EH 00H CKS
ACK
3FH 60H 80H 3EH 00H CKS
06. AUDIO Mute OFF
Function
The external control equipment switches off AUDIO Mute of the plasma
monitor.
Transmission Data
9FH 80H 60H 3FH 00H CKS
ACK
3FH 60H 80H 3FH 00H CKS
01H
00H: Step0
:
0AH: Step10 (Default)
:
2AH: Step42
DATA01
05H
01H
12