Sony AIT-SDX550 Product Specifications Manual page 149

5.25" model
Table of Contents

Advertisement

SEND DIAGNOSTIC
Bit
7
Byte
0
1
Break
2
3
4
Diagnostic Test Number: Number identifying which test to execute
Break: Indicates how to terminate the loop count should an error occur.
0=stop on first error
1=do not stop on error
Loop Count Identifier: The number of times that the test should be repeated before status is returned.
0=Continuous
1=run once
2=run 10 times
3=run 100 times
4=run 1000 times
Parameters A, B, C: Any additional parameters required to fully define the diagnostic test.
If the test completes successfully, the drive returns GOOD status. If the test failed, CHECK CONDITION status is
returned with a HARDWARE ERROR Sense Key and an Additional Sense Code of DIAGNOSTIC FAILURE set. The
Host should then send a REQUEST DIAGNOSTIC command which will return information as to which test failed and
the nature of the failure. If the test requested is not defined, not available to the requested processor, or not
executable in the current configuration, this information will be reported in the data returned by the REQUEST
DIAGNOSTIC command.
Refer to clause 7, Drive Diagnostics for more detailed information about the supported diagnostic tests and test
operations.
SONY AIT-2 Turbo drive SDX-550V series Ver.1.0
Table 6-75: Diagnostic Test information
6
5
4
Diagnostic Test Number
Parameter A
Parameter B
Parameter C
3
2
Loop Count Identifier
6.Command Specification
1
0
6-95