Honeywell IS-215T Installation Instructions page 2

Passive infrared motion sensor
Hide thumbs Also See for IS-215T:

Advertisement

ALARM LED DISABLE
After walk-testing the sensor, disable the alarm
LED by turning Switch S1 to the OFF position.
SPECIFICATIONS
Range:
PIR fields of view:
12 m x 12 m
dual element,
40' x 40'
44 long range zones
14 intermediate, 8 lower,
Power requirements:
4 look-down
10 - 14 VDC, w/LED - Alarm:
10mA max.; w/o LED - Alarm:
Operating temperature:
7mA max.; 12 VDC
-10
3V peak-to-peak at nominal
Relative humidity:
12 VDC
5% to 95% noncondensing
Alarm relay:
Dimensions:
Form A SPST,
8.57 cm x 6.03 cm x 3.81 cm
90 mA, 16 VDC,
(3-3/8" H x 2-3/8" W x 1-1/2" D)
15 Ohm protective resistor
Weight:
Tamper switch
66.62 g (2.35 oz)
Closed with cover in place
Packaged Product is 92.14 g
0.5 A, 30 VDC
(3.25 oz)
RFI immunity:
Approvals/listings:
30 V/m
CE
10 MHz - 1000 MHz
cULus
PIR White light immunity:
C-Tick
6,500 Lux
EN 50131-1
PIR sensitivity:
Security Grade 2
Switch selectable
Environmental Class II
low [normal] (pulse count 2)
3-5 steps
high (pulse count 1) 2-4 steps
Important: For UL Certificated installations, the IS215T must
be connected to a UL listed power supply or UL listed control
unit capable of providing a minimum of four hours of standby
power.
Suitable for connection to an EN 60950 Class II Limited Power
Source.
DETECTION PATTERNS
C to +55
C (14° F to 131° F)
o
o
© 2004 Honeywell International Inc. • Honeywell and IntelliSense are registered trademarks of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved.
TOP VIEW
Wide Angle Lens
SIDE VIEW
Wide Angle Lens
5-051-680-40 Rev C