GE JGP963 - Profile 36" Deep Recessed Gas Cooktop Installation Instructions Manual page 7

36″ sealed gas cooktop
Hide thumbs Also See for JGP963 - Profile 36" Deep Recessed Gas Cooktop:
Table of Contents

Advertisement

Available languages

Available languages

CHECK FOR LEAKS
5
After connecting the cooktop to gas, check
system for leaks with a manometer. If a
manometer is not available, turn the gas
supply on to the cooktop and use a liquid
leak detector at all joints and connections
to check for leaks. Tighten all connections
if necessary to prevent gas leakage in the
cooktop or supply line. Check alignment of
valves after connecting the cooktop to the
gas supply to be sure the manifold pipe has
not been moved. A misalignment could cause
the valve knob stem to rub on the control
panel, resulting in a gas leak at the valve.
DO NOT USE OPEN FLAME TO CHECK
FOR LEAKS!
Disconnect this cooktop and its individual
shutoff valve from the gas supply piping
system during any pressure testing of
that system at test pressures greater than
1/2" psig.
Isolate the cooktop from the gas supply
piping system by closing its individual shutoff
valve during any pressure testing of the gas
supply system at test pressures equal to or
less than 1/2" psig.
Installation Instructions
7
INSTALLATION OVER
6
BUILT-IN OVEN
See built-in oven installation for complete
installation instructions.
90° Street El
Cabinet Sides
5" To Center of
2" Dia. Hole From
Countertop
2" Dia. Hole
(20 7/8" from front
of Countertop to
Hole Center)