SMC Networks 6224M INT - annexe 1 Installation Manual page 10

Tigerstack 10/100 24-port 10/100mbps stackable managed switch
Hide thumbs Also See for 6224M INT - annexe 1:
Table of Contents

Advertisement

C
OMPLIANCES
• This unit operates under SELV (Safety Extra Low Voltage) conditions according to
IEC 60950. The conditions are only maintained if the equipment to which it is connected also
operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point
labelled Neutral, connected directly to earth (ground).
Impédance à la terre
Important! Before making connections, make sure you have the correct cord set. Check it (read the
label on the cable) against the following:
Power Cord Set
U.S.A. and Canada
Denmark
Switzerland
U.K.
Europe
vi
supplies. If your supplies are of IT type, this unit must be
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A
The attachment plug must be an earth-grounding type with NEMA
5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.
The supply plug must comply with Section 107-2-D1, Standard
DK2-1a or DK2-5a.
The supply plug must comply with SEV/ASE 1011.
The supply plug must comply with BS1363 (3-pin 13 A) and be fitted
with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of
type HO3VVF3GO.75 (minimum).
The supply plug must comply with CEE7/7 ("SCHUKO").
The mains cord must be <HAR> or <BASEC> marked and be of
type HO3VVF3GO.75 (minimum).
IEC-320 receptacle.