Fault-Tolerance Features; Table 8. Raid Level Migration - Dell POWEREDGE RADI H700 Technical Manual

Raid controller cards
Hide thumbs Also See for POWEREDGE RADI H700:
Table of Contents

Advertisement

Dell
Source RAID
Target RAID
Level
Level
RAID 0
RAID 1
RAID 0
RAID 5
RAID 0
RAID 6
RAID 1
RAID 0
RAID 1
RAID 5
RAID 1
RAID 6
RAID 5
RAID 0
RAID 5
RAID 6
RAID 6
RAID 0
RAID 6
RAID 5

Fault-Tolerance Features

4.5
Below is a list of features that provide fault tolerance to prevent data loss:
Non-volatile cache: extends data retention from hours to years
Support for SMART
Redundant path support (for PERC H800 only)
Physical disk failure detection
DELL PERC H700 and H800 Technical Guide
Table 8.
RAID Level Migration
# of Physical
# of Physical
Drives
Drives (End)
(Beginning)
1
2
1 or more
3 or more
1 or more
4 or more
2
2 or more
2
3 or more
2
4 or more
3 or more
3 or more
3 or more
4 or more
4 or more
4 or more
4 or more
4 or more
Capacity
Description
Expansion
Possible
No
Converting non-
redundant virtual disk
into a mirrored virtual
disk by adding one drive.
Yes
At least one drive needs
to be added for
distributed parity data.
Yes
At least two drives need
to be added for dual
distributed parity data.
Yes
Removes redundancy
while increasing
capacity.
Yes
Maintains redundancy
while doubling capacity.
Yes
Two drives are required
to be added for
distributed parity data.
Yes
Converting to a non-
redundant virtual disk
and reclaiming disk space
used for distributed
parity data.
Yes
At least one drive needs
to be added for dual
distributed parity data.
Yes
Converting to a non-
redundant virtual disk
and reclaiming disk space
used for distributed
parity data.
Yes
Removing one set of
parity data and
reclaiming disk space
used for it.
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge raid h800Perc h700Perc h800

Table of Contents