Start-Up Checklist; Lighting Procedure - Dansons Group CAN/CSA B365 Operation Manual

Dansons group inc. pellet stove can/csa b365 operations guide
Table of Contents

Advertisement

STARTUP CHECKLIST
1
Please make certain you have completed the
following checklist before proceeding:
.
Unit is plugged into a 3 pronged grounded outlet
.
Burn pot is clean, level & seated properly
.
Front door of the stove is closed
.
Screened pellets are in the hopper
.
Pellet fuel complies with PFI standards (pelletheat.org)
.
Unit is NOT plugged into a GFI outlet
FOR NEW INSTALLATIONS:
.
Used only PL or L approved venting
.
Sealed vent connections with high temp RTV sealant
and allow sealant to cure for 24 hours
.
Make sure #1 trim pod is set to 9 o'clock position
.
Air inlet damper is OPEN to between 1/4" and 1/2"
(see 'Initial Setup' section on page 4)
We STRONGLY recommend the use of a surge protector
to protect the circuitry in your control board.

LIGHTING PROCEDURE

2
Push firmly on the START / FEED RATE button.
The COMBUSTION FAN (exhaust) will start and operate at full speed for 60 seconds, then will slow
A
to match the startup rate
The CONVECTION FAN (heat circulation) will start and the LED will go solid on LOW setting
B
The AUGER CYCLE LED will go solid for 3 seconds indicating the signal is being sent to auger motor
C
The IGNITER LED will light up solid and the igniter will begin to heat up
D
3
On a primed auger system, pellets will begin to fall into the BURN GRATE,
and the igniter will automatically ignite pellets in approximately
3 to 7 minutes.
During first-time startup procedure,
your auger system IS NOT PRIMED
(meaning pellets have not filled the
entire auger system yet). To solve this,
simply press theSTART / FEED RATE
button again.
4
Adjust FUEL RATE and FAN
SPEED to your desired settings
(see PELLET STOVE ADJUSTMENTS
.
section)
NOTE: New stoves can emanate an odor during the initial few hours of burning while the paint cures.
Ventilating the room is strongly recommended until the odors disappear.
YOUR PELLET STOVE
(ground fault interruptor)
(see pg 5)
SAMPLE GRATE
WITH PELLETS
BURN
POT
If the fire does not start, your stove will continue to feed pellets and
run the fans for 15 minutes. The stove will then automatically shut off.
If the stove fails to ignite a second time, refer to the
section of your manual or contact your pellet stove dealer.
STARTING UP
Procedures listed will work with both
AcuTron II & AcuTron III control boards.
PRIMED
AUGER
SYSTEM
SAMPLE IGNITER
TROUBLESHOOTING
HOPPER
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

FppIppCc1Cc2Cc3Ccgb1 ... Show all

Table of Contents