1hps belt drive battery backup garage door opener (48 pages)
Summary of Contents for Chamberlain Whisper Drive Security+ WD952KCD
Page 1
The door WILL NOT CLOSE unless The Protector System ® is connected and properly aligned. ■ Periodic checks of the opener are required to ensure safe operation. ■ The model number label is located on the front panel of your opener.
Safety Symbol and Signal Word Review This garage door opener has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual. When you see these Safety Symbols and Signal...
BEFORE installing and operating garage WARNING 2. Raise and lower the door to see if there is any door opener to avoid entanglement. binding or sticking. If your door binds, sticks, or is out of balance, call a CAUTION trained door systems technician.
• Installation Step 10 – Alternate floor mounting of and 11. the safety reversing sensor will require hardware • If your door is more than 7 feet (2.13 m) high, see not provided. rail extension kits listed on Accessories page.
Page 5
If your door is lightweight, refer to door. the information relating to sectional doors in • The gap between the bottom of the garage door and Installation Step 11. the floor MUST NOT exceed 1/4" (6 mm). Otherwise, WARNING •...
Carton Inventory Your garage door opener is packaged in one carton packing material. Parts may be stuck in the foam. which contains the motor unit and all parts illustrated Hardware for assembly and installation is shown on below. Accessories will depend on the model the next page.
Hardware Inventory Separate all hardware and group as shown below for the assembly and installation procedures. ASSEMBLY HARDWARE Lock Washer Lock Nut Spring/Trolley Nut (1) 3/8" (1) 3/8" (1) 1/4"-20 (2) Bolt 1/4"-20x1-3/4" (2) Master Link Idler Bolt (1) Trolley Threaded Shaft (1)
To avoid installation difficulties, do not run the garage door opener until instructed to do so. The front rail has a cut out “window” at the door end 3. Place the motor unit on packing material to protect (see illustration). The hole above this window is the cover, and rest the back end of the rail on top.
ONLY those bolts/fasteners mounted in the top of the • Insert a 1/4"-20x1-3/4" bolt into the cover opener. protection bolt hole on the back end of the rail as shown. Tighten securely with a 1/4"-20 lock nut. Do NOT overtighten.
Be sure the belt is not twisted, and the ribbed side faces the rail. Hex Screw 8x3/8" 6. Hold the belt at the trolley shaft as you thread the Spring/Trolley Nut spring nut by hand onto the shaft until finger tight against the trolley.
• within sight of the garage door. SEVERE INJURY or DEATH. • out of reach of children at minimum height of 5 feet 3. ALL repairs to cables, spring assemblies and other (1.5 m).
Track Highest Point only if a torsion spring or center bearing plate of Travel Highest Point is in the way; or you can attach it to the ceiling of Travel (see page 13) when clearance is minimal. (It Door Door may be mounted on the wall upside down if necessary, to gain approximately 1/2"...
• Extend the vertical centerline onto the ceiling as shown. • Center the bracket on the vertical mark, no more than 6" (15 cm) from the wall. Make sure the arrow is pointing away from the wall. The bracket can be mounted flush against the ceiling when clearance is minimal.
• Position the rail bracket against the header bracket. Header Wall • Align the bracket holes and join with a clevis pin Header Bracket 5/16"x1-1/2" as shown. Idler Pulley • Insert a ring fastener to secure.
• Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough. • Open the door all the way and place a 2x4 laid flat on the top section beneath the rail.
Structural provided. Supports Existing brackets from a previous installation may be fastened to the sides of the motor unit as in Figures Lag Screws 1 and 2, or to the mounting tabs as shown in 5/16"- 18x1-7/8" Figure 3. Then continue with step 5 below.
2 and white/red wire to the 1. • Activate door ONLY when it can be seen clearly, is 2. Remove cover by gently prying at slot in top of the properly adjusted and there are no obstructions to door cover with a small flat head screwdriver. Fasten travel.
• If possible, use emergency release handle to disengage • Thread one end of the rope through the hole in the trolley ONLY when garage door is CLOSED. Weak or top of the red handle so “NOTICE” reads right side broken springs or unbalanced door could result in an up as shown.
• NEVER use an extension cord, 2-wire adapter, or proper outlet. change plug in any way to make it fit outlet. Be sure the opener is grounded. PERMANENT WIRING CONNECTION RIGHT...
If it is necessary to mount the units on the wall, the position, and the opener lights will flash 10 times.
Page 21
• Use bracket mounting holes as a template to locate Lag Screws and drill (2) 3/16" diameter pilot holes on the wall (Not Provided) at each side of the door, no higher than 6" (15 cm) Lens above the floor. • Attach brackets to wall with lag screws (Not provided).
SENSORS ceiling. 1. If the sending eye indicator light does not glow • Strip 7/16" (11 mm) of insulation from each set of steadily after installation, check for: wires. Separate white and white/black wires • Electric power to the opener.
(Figure 3). Reinforcement Board Bolt Wood Doors: 5/16"x2" • Use top and bottom or side to side door bracket holes. Drill 5/16" holes through the door and secure bracket with 5/16"x2" carriage bolts, lock washers Vertical Centerline and nuts (not provided) (Figure 4).
Page 24
They apply to one-piece doors also. • Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes.
5/16"-18 (15 cm) from the solid end. Reconnect to trolley with cut end down as shown. – Bring arm sections together. – Find two pairs of holes that line up and join with Bolts 5/16"-18x7/8" bolts, lock washers and nuts.
Page 26
• The trolley will automatically connect. If not, review the trolley lockout feature on page 31. • When setting the up limit on the following page, the door should not have a “backward” slant when fully open as illustrated below. A slight...
This sets the UP (open) limit and begins closing the door. Immediately press either the black or purple button; the door will stop. 4. Open and close the door with the remote control or Adjust the desired DOWN (close) limit position door control 2 or 3 times.
• After ANY adjustments are made, the safety reversal and close the door. system MUST be tested. Door MUST reverse on 1. Locate the purple button on the back panel of unit contact with 1-1/2" high (3.8 cm) object (or 2x4 laid WARNING (Figure 1).
TEST SERIOUSLY INJURED or KILLED by a closing garage door. • With the door fully open, place a 1-1/2" (3.8 cm) • Safety reversal system MUST be tested every month. board (or a 2x4 laid flat) on the floor, centered •...
10. Safety reversal system MUST be tested every month. 3. ONLY activate garage door when it can be seen clearly, it Garage door MUST reverse on contact with 1-1/2" is properly adjusted and there are no obstructions to (3.8 cm) high object (or a 2x4 laid flat) on the floor.
Press the Light button to turn the opener light on or off. It will not control the opener lights when the door is in motion. If you turn it on and then activate the To prevent possible SERIOUS INJURY or DEATH from a opener, the light will remain on for 4-1/2 minutes.
Page 32
The BBU can be electrocution, disconnect power to motor unit BEFORE CAUTION WARNING mounted directly on top of the motor unit or it can be proceeding. secured on a structural support just above it. 2. Mounting the BBU Directly to the Ceiling Holes for Ceiling Mount Structural Support.
Battery Backup Unit (BBU) Diagnostics WARNING WARNING To reduce the risk of FIRE or INJURY to persons use only Chamberlain part #41B591 for replacement (Yellow LED) CAUTION WARNING (Red LED) (Green LED) batteries. OPERATING INSTRUCTIONS 1. Test the installed BBU with the motor unit.
THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
• Manually bring the door to a closed position. adjustment for the force and limit settings is • Loosen the belt by adjusting the outer nut 4 to 5 normal. Weather conditions in particular can affect turns. This relieves the tension.
Possible RPM sensor • Unplug unit to reset. Try to operate motor unit, check diagnostic code. failure. • If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace RPM Unplug to reset. sensor. • If motor unit doesn’t operate, replace logic board.
The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code transmitter to circumvent that technical measure.
To Add, Reprogram or Change a Keyless Entry PIN NOTE: Your new Keyless Entry must be programmed to operate your garage door opener. USING THE “LEARN” BUTTON USING THE MOTION DETECTING CONTROL PANEL 1. Press and release the “learn” NOTE: This method requires two people if the Keyless button on motor unit.
Curved door arm section 178B34 Straight door arm section 12B776 Hanging bracket 41A5034 Safety sensor kit: receiving and sending eyes with 3' (.9 m) 2-conductor bell wire attached 41A5266-1 Safety sensor bracket NOT SHOWN 41A5257-9 Installation hardware bag (includes hardware listed on page 7) 114A3213 Owner’s manual...
Belt cap and sprocket 41B5351-7 Power supply 41B4245 Line cord 41C168 Transformer and harness 41B4375-2 Terminal block w/screws 41D630 Bracket: light socket, limit switch 41C5317 Wire harness (logic) 41A5490-17 Cover 41C5839 High voltage wire harness 175C147 Light socket 41C5806 DC motor wire harness...
This temporary password can be limited to a programmable number of hours or entries. 10 Foot (3 m) Rail Extension: 8810C To allow a 10 foot (3 m) door to open 945C Multi-Button Door Control Panel: fully. Provides a Lock feature which...
The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of one year from the date of purchase and that the motor is free from defect in materials and/or workmanship for the lifetime of the product, and the belt is free from defect in materials and/or workmanship for a period of 10 years from the date of purchase.
Page 43
Manuel d’instructions ■ Lire attentivement ce manuel ainsi que les consignes de sécurité! ■ Après la pose, accrocher ce manuel près de la porte de garage pour s’y reporter ultérieurement. ■ La porte NE SE FERMERA PAS si Le Système Protector ®...
Page 44
AVERTISSEMENT Cet ouvre-porte de garage a été conçu et testé dans le but d’offrir un service sûr à condition qu’il soit installé, utilisé, entretenu et testé en stricte conformité avec les instructions et les avertissements contenus dans le présent manuel.
: • TOUJOURS désactiver les serrures AVANT de poser et d’utiliser l’ouvre-porte. • Faire fonctionner l’ouvre-porte de garage UNIQUEMENT à une tension de 120 V, 60 Hz pour éviter les défauts de fonctionnement et les dommages. Porte articulée Outils nécessaires Porte rigide Lors de l’assemblage, de la pose et du réglage de...
L’espace entre le plancher déclenchement Détecteur inverseur de sécurité et le bas de la porte ne doit pas être supérieur à 1/4 de po (6 mm). d'urgence Biellette Linteau courbée Support de porte...
Page 47
à la 11 AVERTISSEMENT • L’espace entre le bas de la porte et le plancher NE DOIT PAS opération de pose. dépasser 1/4 de po (6 mm), sinon le système d’inversion de •...
A gr a f e de pare-solei l Télécommande pour télécommande à trois boutons (2) P anneau de commande de po r te a v ec détection de mou v ement Unité batterie de secours Chariot Capuchon de maintien de la courroie Système d'ouverture sans clé...
Inventaire des fixations Séparer toutes les fixations et les regrouper comme illustré ci-après aux fins des opérations de montage et de pose. FIXATIONS POUR LE MONTAGE Écrou de Contre-écrou de Rondelle-frein Écrou de chariot/ressort (1) 1/4 de po-20 (2) de 3/8 de po (1)
Un support sous l’extrémité avant du rail. plus petit trou à 3-1/2 de po (8,9 cm) de distance se trouve 4. Comme boutoir temporaire, insérez un tournevis dans près du bord du rail. Faire tourner le rail arrière de manière l’orifice situé...
Afin d’éviter d’endommager SÉRIEUSEMENT l’ouvre-porte de garage, utiliser UNIQUEMENT les boulons et les fixations • Insérer un boulon de 1/4 de po-20 x 1-3/4 de po dans le montés sur le dessus de l’ouvre-porte. trou du boulon de protection du couvercle à l’extrémité...
3. Le chariot étant contre les tournevis, distribuer le reste de la courroie le long du rail vers le moteur et autour du pignon. Les dents du pignon doivent s’engager dans la courroie.
La porte DOIT remonter au contact d’un objet d’une 6. Monter la poignée de déclenchement d’urgence à 6 pieds hauteur de 1-1/2 po (3,8 cm) (ou un 2 x 4 posé à plat) sur le (1,83 m) au-dessus du sol.
Porte au besoin, pour gagner environ 1/2 de po (1 cm).) Si l’on doit poser le support de linteau sur un 2 x 4 (au mur ou au plafond), utiliser des tire-fond (non fournis) pour s’assurer que le 2 x 4 est bien retenu sur les solives, comme montré...
POSE DU SUPPORT DE LINTEAU AU PLAFOND • Prolonger l’axe vertical sur le plafond, comme illustré. • Centrer le support sur l’axe vertical à 6 pouces (15 cm) au maximum du mur. S’assurer que la flèche est orientée dans le sens opposé au mur. Le support peut être encastré...
• Positionner le support du rail contre le support de linteau. Linteau • Aligner les trous des supports et les raccorder avec un Support de linteau axe de chape de 5/16 de po x 1-1/2 de po, comme il est Poulie illustré. • Introduire un anneau d'arrêt pour immobiliser.
Positionnement de l'ouvre-porte Pour prévenir les dommages à la porte de garage, faire reposer le rail de l’ouvre-porte de garage sur un 2 x 4 placé sur la Suivre les instructions qui se rapportent à la porte de section supérieure de la porte.
Rondelle-frein de 5/16 de po les solives. Écrou de 5/16 de po-18 4. Fixer une extrémité de chaque support de suspension sur une solive avec des tire-fond de 5/16 de po -18 x Région préférée de positionnement de 1-7/8 de po.
Poser la commande murale dans un endroit où on pourra • S’assurer que le courant est coupé AVANT de poser la la voir de la porte, à au moins 5 pieds (1,5 m) du sol, là où commande de porte.
• Ne JAMAIS utiliser la poignée pour ouvrir ou fermer la porte. soit à environ 6 pieds (1,83 m) du sol. S’assurer que la Il y a risque de chute si le nœud de la corde se défait. corde et la poignée ne risquent pas de toucher au capot d’aucun véhicule pour éviter qu’elle s’emmêle.
à un branchement permanent. Afin de minimiser les risques de chocs électriques, le • La pose et le câblage de la porte de garage DOIVENT être cordon d'alimentation de l'ouvre-porte de garage comporte conformes à tous les codes électriques et de construction une fiche à...
• Poser le détecteur inverseur de sécurité de manière à ce que Lorsqu’il est bien raccordé et aligné, le détecteur détecte le faisceau NE SOIT PAS À UNE HAUTEUR de plus de 6 po un obstacle dans le parcours de son faisceau électronique.
Page 63
Guide de porte la porte du garage, le faisceau n’étant pas à une hauteur de plus de 6 po (15 cm) au-dessus du sol. Ils peuvent être Rebord posés de trois façons, suivant vos exigences, comme suit : Témoin...
Page 64
Figure 5 INVERSEURS DE SÉCURITÉ Écrou à oreilles • Faire glisser un boulon à tête bombée et collet carré de 1/4 de po-20 x 1/2 de po dans la fente de chaque détecteur. Utiliser des écrous à oreilles pour fixer les détecteurs aux supports, avec les diffuseurs dirigés l’un...
à l’aide de boulons à vertical de la porte de garage tête bombée et à collet carré de 5/16 de po x 2 po, des rondelles de blocage et des écrous (non fournis). autotaraudeuse...
Page 66
à la page précédente. Ils s’appliquent également aux portes rigides. • Centrer le support de porte sur le dessus de la porte, en l'alignant avec le support de linteau, comme il est illustré. Repérer soit les trous de gauche et de droite, soit les trous du haut et du bas.
– Fixer la biellette droite sur le chariot extérieur à l'aide Axe de chape courbée d'un axe de chape de 5/16 de po x 1 po. Faire tenir de 5/16 de po l'axe de chape en place avec un anneau d'arrêt.
Page 68
• Connecter la biellette courbée au chariot à l’aide de l’axe de chape de 5/16 de po x 1-1/4 de po et de l’anneau d’arrêt. REMARQUE: Réglage de la fin de course de la page suivante: •...
AVERTISS faire l’essai du système d’inversion de sécurité. La porte de garage DOIT remonter au contact d’un objet d’une hauteur de 1-1/2 po (3,8 cm) (ou un 2 x 4 posé à plat) sur le sol. AVERTISSEMENT Figure 1 Témoin...
DOIT remonter au contact d’un objet d’une hauteur du moteur (Figure 1). de 1-1/2 po (3,8 cm) (ou un 2 x 4 posé à plat) sur le sol. 2. Appuyer deux fois sur le bouton mauve pour placer l’unité en mode de Réglage de la force (Figure 2). Le voyant LED (témoin lumineux) se mettra à...
• Fermer la porte. La porte doit remonter dès qu'elle garage DOIT remonter au contact d’un objet d’une hauteur touche l’obstacle. de 1-1/2 po (3,8 cm) (ou un 2 x 4 posé à plat) sur le sol. RÉGLAGE • Si la porte s'arrête sur l’obstacle, sa course de fermeture n'est pas suffisante.
8. Ne JAMAIS utiliser la poignée pour ouvrir ou fermer la porte. INSTRUCTIONS. Il y a risque de chute si le nœud de la corde se défait. 2. TOUJOURS garder les télécommandes hors de la portée des 9. Après avoir effectué quelque réglage que ce soit, on DOIT faire enfants.
• Ne JAMAIS utiliser la poignée pour ouvrir ou fermer la porte. 3-1/2 minutes, etc., jusqu’à un maximum de quatre Il y a risque de chute si le nœud de la corde se défait. clignotements pour 4-1/2 minutes. Fonction d’éclairage automatique POUR DÉGAGER LE CHARIOT :...
Fentes pour de la batterie de secours. vis - Montage sur châssis • Fixer la batterie de secours au plafond en utilisant les vis Vis tire-fond tire-fond de 1-1/2 de pouce (fournies). de 1-1/2 de po 1. Montage de la batterie de secours directement 3.
Page 75
2 secondes environ indique que le moteur • Permettre aux accumulateurs de se charger tourne pour ouvrir la porte et qu’il le fait en s’alimentant à complètement, pendant 24 à 48 heures, avant d’utiliser le partir de la batterie de secours.
Ne pas graisser les guides de la porte. Se débarrasser de la pile usagée convenablement. AVIS : Les règles de la FCC ou d’Industrie Canada (IC), ou les deux, interdisent tout ajustement ou toute modification de ce récepteur et/ou de cet émetteur, sauf pour modifier le code ou pour remplacer la pile.
• Fermer la porte manuellement. • Vérifier manuellement que la porte est bien équilibrée • Relâcher la courroie en donnant 4 à 5 tours à l’écrou et qu’il n’y a pas de problèmes d’adhésion. extérieur, ce qui relâche la tension.
éventuelle panne du capteur le code de diagnostic. de régime. Débrancher pour • S’il émet encore 5 éclairs et que le moteur se déplace de 6-8 po (15 à 20 cm), le réarmer. remplacer le capteur de régime. • Si le moteur ne fonctionne pas, le moteur a surchauffé. Attendre 30 minutes et essayer à...
émettrice à code fixe, le dispositif technique que contient le récepteur de l’ouvre-porte et qui procure une protection contre les vols de code, se trouvera contourné. Le détenteur des droits d’auteur de cet ouvre-porte de garage n’autorise pas l’acheteur ni le fournisseur de la télécommande émettrice à...
Un bouton fermé: L’ouvreur peut être fermé en appuyant sur le bouton ENTER si le dispositif du bouton fermé a été activé. Ce dispositif a été activé par le fabricant. Afin d’activer ou de désactiver ce dispositif, appuyez et maintenez les boutons 1 et 9 enfoncés pendant 10 secondes.
émettrice) avec fil de sonnerie 3 pi (.9 m) à 2 conducteurs 41A5266-1 Support de détecteur inverseur de sécurité NON ILLUSTRÉS 41A5257-9 Sac de fixations de montage et de pose (se reporter à la page 7) 114A3213 Manuel d’instructions...
41C168 Transformateur avec harnais 41B4245 Cordon électrique 41D630 Support de: douille d’ampoule, 41B4375-2 Bornier avec vis d’interrupteur de fin de course 41C5317 Wire harness (logic) 41A5490-17 Couvercler 41C5839 Ensemble de faisceaux de fils 175C147 Douille d’ampoule à haute tension...
940CD Entrée sans clé SECURITY✚ ® 8808C Rallonge de rail de 8 pieds (2,4 m) : Permet d’ouvrir la porte de l’extérieur en Pour permettre à une porte de 8 pieds entrant un mot de passe sur le clavier de (2,4 m) de s'ouvrir complètement.
à compter de la date d’achat et que et courrole est exempt de défaut de matière et/ou vice de fabrication pour une période de dies ans et le moteur est exempt défaut de matière et/ou vice defabrication pour le vie de produit.